Byron Home easy HE-430 Installation Manual Download Page 1

RE-INVENTING THE HOME

HOME

easy

HE-430 Outdoor  Remote 

Control 3 Gang Kit 

V1.0

OFF:  An additional safety feature of the HE430 is the ability to switch off the 
power as per a normal socket.
Unused accessory Channels should be set to OFF

INSTALLATION WARNING:

ON INSTALLATION TURN OFF YOUR MAINS ELECTRIC SUPPLY

This product should be fitted by a competent person  in accordance with the 

instructions listed below and with the relevant clauses of the IEE wiring regulations

BS7671.

For fixed installation only

1. Remove the front cover by
unscrewing the 4 corner screws as 
shown.

Installation Guide:

Wiring Remote Socket:

On the outdoor enclosure you will see that there are a number of rubber entry spaces
(ÎEntry blanksÌ) on each side, depending on location and wiring setup a number of 
these can be removed.

If installing the HE430 with conduit from the sides or top attachment, a 5mm hole 
must be drilled through the bottom left drainage hole. This will allow for any 
condensation forming in the conduit, to drain out.
Caution: opening the drainage hole will affect the IP rating of the product. Ensure that 
jetted water is not directly sprayed onto the unit.

Do Not drill out the drainage hole when installing the Outdoor socket  into a dusty
environment. Always install the unit via the bottom cable entry, making sure that a 5mm 
hole is drilled into the lowest point in the conduit system.

The HE-430 allows you to control up to 3 
separate outdoor electrical products 
independently using the Home Easy 
remote control timer, with a maximum  
load of 400W per channel. 

AUTO: Allows the Remote Control to switch  on/off 
the HE430. See Pairing/Deleting  with Remote

ON: Sets the Outdoor socket as a standard outdoor socket. 

-Selectable timer setting
-8 Programmable memory Settings
-Security Mode Setting
 -Single and Daily Timer Functions

easy

HOME

The  HE430 should be used in conjunction with a fused spur connection, all connections 

to the socket need to be made as instructed, making sure that the cable used is 

appropriate for the installation environment, free from stress & terminals are tightened 

fully.

-IP55 Weather Proof
-30 Metre Wire Free Range
-CR2032/23A Battery (Included)

Product Specification:

3 Gang Remote Control Receiver: HE-430
  Input: 230V - 240V ~50Hz
  Range: 30 Metres (Open Distance)
  Frequency: 433.92MHz
  Max Load: 3 x 400W
 (Combined Resistive load)
  IP55 (Lid Closed)

Warning: Never Exceed the Product Specification

Remote Control:  HE-200
  Battery:  23A & CR2032 (Included)
  Range: 30Metres (Open Distance)
  Frequency: 433.92MHz
  Indoor use only

3. Using the back half of the unit as a template, mark 
all four corners onto your chosen surface.
Drill and use appropriate fixings to secure to the surface.  

2: In the back half of the unit, in all four corners are 
purpose made holes for fixing your HE430 to your 
intended surface. The HE430 needs to be mounted 
onto a flat, vertical surface, free from grease, loose 
material and any corrosive substances. We 
recommend a house or sturdy garden wall.

Recommended Setup:

Voltage In:
230-240V ~ 50Hz

C

hannel 3 Out

C

hannel 1 Out

C

hannel 2 Out

Once the entry blanks are
removed, appropriate cable
glands need to be installed (not 
included).

Input Power: (See Wiring Diagram)
1: Switch off and isolate the mains power before Installing or altering the electrical 
connections and remove the terminal covers.

2: Send the cable through the gland and into the HE430.

3: Cut back the cable to reveal the 3 separate wires

L= Live

Brown

E= Earth

Green & Yellow

N= Neutral

Blue

4: Now strip each wire, exposing 10mm of its core

5: Insert the exposed core wires into their related terminals 
and clamp down by tightening the respective screws. 
Replace the terminal covers and tighten the cable glands, 
(not included) making sure all wires are secure.

Wiring Diagram:  

HE430

HE200

WARNING:
You MUST install an earth cable between the origin of the installation and the earth
terminal of the outdoor socket.This must be insulated inside a sleeve protector within 
the conduit.
If using metal conduit, earth continuity must be maintained between conduits. Seal
Conduit and conduit entry with a non setting conduit sealant. Purchasable form you
local electrical retailer.

Operating Mode:

Output:
230-240V ~ 50Hz
3 x 400W Combined 
Max Load

6. Reconnect the mains power, the HE430 is now ready for programming 
(See Pairing/Deleting  with Remote). 
Replace the front cover and tighten the screws. 

Each Acessory Output Channel can operate in 3 seperate modes, use the slide 
switch on each channel to  select the mode setting.

Features:

Reviews: