5
INSTALLATION COMPLETION
1.
INSTALL PLACARDS AND SAFETY EQUIPMENT AND TEST.
2.
“REMOVE” ALL DEBRIS AND OBSTRUCTIONS FROM THE TRAVEL PATH OF THE GATE
LEAF(S).
3.
TURN ON AND LABEL THE COMMERCIAL POWER CIRCUIT BREAKER AND REMOVE THE
“USED” TAG YOU INSTALLED AT THE BEGINNING OF THE PROJECT.
4.
USING THE MANUAL BYPASS, POSITION THE GATE LEAF AT 45 DEGREES. PRESS THE
TEST BUTTON ON THE G2M CONTROL BOARD. THE FIRST SIGNAL WILL ALWAYS BE TO
OPEN. IF THE OPERATOR RUNS TO THE CLOSED POSITION, TURN OFF THE COMMERCIAL
POWER AND REVERSE THE MOTOR CONNECTIONS ON PINS 1 AND 3.
5.
OPERATE THE ACTUATOR SEVERAL TIMES UNTIL YOU CAN DETECT A RISE IN THE
FLUID TEMPERATURE. PLACING YOUR HAND ON THE TOP OF THE OPERATOR AT THE
REAR CAN DO THIS.
6.
PURGE AND ADJUST THE OPERATOR AS DESCRIBED IN THE PURGING AND ADJUSTMENT
SECTION.
7.
INSTRUCT THE END USER HOW TO MANUALLY RELEASE THE GATE IN THE EVENT OF A
POWER FAILURE.
8.
INSTRUCT THE END USER HOW TO PROPERLY OPERATE THE GATE AUTOMATION AND
SAFETY FEATURES THEREOF.
9.
COLLECT THE “SIGNED” END USER SAFETY HAND OUT. BY THEIR SIGNATURE, THE END
USER ACKNOWLEDGES THEIR UNDERSTANDING OF THEIR RESPONSIBILITIES OF
OWNING, OPERATING, AND MAINTAINING A VEHICULAR AUTOMATIC GATE OPERATING
SYSTEM.