background image

2

This bXterra product is constructed to provide unmatched power protection, quality and 

performance for the duration of its lifetime. Please take a few minutes to register your new product 

at 

www.bXterra.com/registration

. Registration certifies your product’s warranty, confirms your 

ownership in the event of a product loss or theft and entitles you to free technical support. Please 

register your product now to receive the benefits of bXterra ownership.  

WARRANTY & REGISTRATION

SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS: 

This manual 

contains important instructions that should be 

followed during installation and maintenance of 

the UPS and its batteries.

1. 

This unit is intended for installation in a 

controlled environment (a temperature-

controlled and indoor area free of 

conductive contaminants). Please avoid 

installing the UPS in locations where 

there is standing or running water, dust, 

direct sunlight or excessive humidity. 

2. 

This UPS utilizes voltage that may 

be hazardous. Do not attempt to 

disassemble the unit. Only factory service 

personnel may perform repairs.

3. 

Connect your UPS directly to a properly-

grounded AC power outlet with fuse or 

circuit breaker protection. Do not plug the 

unit into an outlet that is not grounded. 

Turn off and unplug the unit if you need 

to de-energize it.

4. 

Not for use in a computer room as 

defined in the Standard for the Protection 

of Electronic Computer/Data Processing 

Equipment, ANSI/NFPA 75.  

5. 

To reduce the risk of fire, connect only 

to a circuit provided with 20 amperes 

maximum branch circuit over current 

protection in accordance with the 

National Electric Code, ANSI/NFPA 70.  

6. 

For best performance, keep the indoor 

temperature around the unit between 32⁰ 

F and 104 ⁰F (0 ⁰C and 40 ⁰C).  

7. 

Do not attach medical equipment or 

non-computer related items, such as life-

support equipment, microwave ovens, or 

vacuum cleaners to the UPS. bXterra does 

not sell equipment meant for life-support 

or medical applications. Visit our website 

for more information about devices 

appropriate to plug into this UPS. 

8. 

Only stand or set up the UPS in the 

direction specified in the Installation 

and Operation section of this manual. 

Do not block fans and leave adequate 

space around all sides of the UPS for 

proper ventilation. Do not expose the 

unit to direct sunlight and do not install 

the unit near heat-emitting appliances 

such as a space heater or furnace. This 

could negatively impact the unit’s internal 

cooling system and cause product 

damage not covered under warranty.    

9. 

Do not plug the UPS input into its own 

output. Do not attach a power strip or 

surge protector to the UPS. 

10. 

Do not modify the UPS’s plug and do not 

use an adapter that would eliminate the 

UPS’s ground connection.

11. 

Do not use extension cords to connect 

the UPS to an AC outlet. 

12. 

If the UPS receives power from a motor-

powered AC generator, the generator 

must provide clean, filtered, computer-

grade output. Consult your generator’s 

manual to see if it meets these 

specifications.

13. 

The main power outlet that supplies the 

UPS should be easily accessible and near 

the UPS.   

14. 

To reduce the risk of fire or electric shock, 

do not use the unit on any transportation 

such as airplanes or ships. The effect of 

shock or vibration caused during transit 

and the damp environment can cause the 

unit to short out. 

 

BATTERY WARNINGS:

Servicing of batteries should be performed or 

supervised by personnel knowledgeable about 

batteries and the required precautions. When 

replacing batteries, replace with the same type 

and number of batteries or battery packs. 

CAUTION: Do not dispose of batteries in a fire. 

The batteries may explode. 

 

CAUTION: Do not open or mutilate batteries. 

Released electrolytes are harmful to the skin 

and eyes. It may be toxic. 

 
CAUTION: A battery can present a risk of 

electrical shock and high short-circuit current. 

Contact with any part of a grounded battery 

can result in electrical shock. 

The following precautions should be observed 

when working on batteries:

a) Remove watches, rings or other metal 

objects

b) Use tools with insulated handles

c) Wear rubber gloves and boots

d) Do not lay tools or metal parts on top of 

batteries

Summary of Contents for BG 550

Page 1: ...USER MANUAL bxterra com BM INTELLIGENT LCD UPS BM850LCD BM750LCD BM550LCD ...

Page 2: ...Y INSTRUCTIONS INSTALLATION OPERATION CERTIFICATIONS PRODUCT OVERVIEW BATTERY REPLACEMENT LCD DISPLAY TROUBLESHOOTING TECHNICAL SPECIFICATIONS WARRANTY INFORMATION CONSIGNES DE SÉCURITÉ INFORMATIONS DE GARANTIE 2 2 3 3 4 4 5 5 6 7 8 8 9 10 11 11 11 ...

Page 3: ...te for more information about devices appropriate to plug into this UPS 8 Only stand or set up the UPS in the direction specified in the Installation and Operation section of this manual Do not block fans and leave adequate space around all sides of the UPS for proper ventilation Do not expose the unit to direct sunlight and do not install the unit near heat emitting appliances such as a space hea...

Page 4: ...t results charge the battery for six hours prior to initial use When the UPS is plugged into an AC outlet the battery will automatically charge whether the UPS is turned on or not PLUG IN EQUIPMENT Battery Backup Outlets With the UPS turned off and unplugged connect equipment requiring battery backup to the Battery Backup outlets These outlets provide battery backup EMI filtering line conditioning...

Page 5: ...WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment GREENTECH UPS HIGH EFFICIENCY DESIGN A highly efficient bXterra GreenTech UPS can reduce your negative environmental impact and save you money By implementing high quality components and leading edge design GreenTech UPS systems strive to deliver ...

Page 6: ...software PowerFrame Instructions for this procedure can be found in the Installation and Operation section of this manual 8 Phone network surge protection These ports protect equipment from surges over a single phone line or network connection 9 Circuit breaker This breaker provides overload and fault protection If it trips remove some of the load then reset it by pressing it in 10 Coax surge prot...

Page 7: ...ge 2 Output frequency 3 Load percent 4 Input voltage 5 Input frequency 6 Estimated time 7 Battery level Press button to cycle through the displayed information Off Site Wiring Fault in AC Mode On 1 indicator is flashing every second 2 and normal AC Mode will take turns flashing every five seconds Off AC Mode in Mute On indicator will display Off The mute function can be set but can only be used in...

Page 8: ...cond Beeping every 0 5 seconds Battery Mode in Mute On indicator will display The UPS will not sound an alarm until after an event occurs such as low battery overload etc Output Short Circuited On Disconnect short circuited loads and restart the UPS Continuously beeping Overload Fault On Turn off the UPS Disconnect all loads and restart the UPS Plug in equipment one at a time and make sure not to ...

Page 9: ...S off and unplug one piece of equipment Wait 10 seconds reset the circuit breaker then turn the UPS on again The UPS will not turn on The on off switch is designed so the user must press the button for at least 2 seconds to turn it on Turn the UPS off Wait 10 seconds then turn it on again The unit is not plugged into an outlet The unit must be connected to a properly grounded outlet providing 110 ...

Page 10: ...nance free sealed lead acid battery Battery Size 12V 7 0Ah 12V 9 0Ah 12V9 0Ah Battery Model DJW12 7 0 MS7 12 DJW12 9 0 MS9 12 Battery Quantity 1 User Replaceable Yes Recharge Time 8 Hours SURGE PROTECTION FILTERING Surge Suppression 1 030 Joules 1 030 Joules 1 030 Joules Phone RJ11 Ethernet RJ45 Yes EMI RFI Filtration Yes MANAGEMENT COMMUNICATIONS Multi status LCD Panel Voltage Frequency Runtime L...

Page 11: ...pareil entre 0 C et 40 C 32 F et 104 F 7 Ne fixez pas d équipement médical ou d articles non liés à l ordinateur tels que des équipements de survie des fours à micro ondes ou des aspirateurs à l UPS bXterra ne vend pas d équipements destinés à des applications médicales ou de survie Visitez notre site Web pour plus d informations sur les WARRANTY INFORMATION Your bXterra product comes with a Limit...

Page 12: ...t de fabrication du produit pendant 3 ans à compter de la date d achat S il est prouvé que le produit présente un vice de matériau ou de fabrication au cours de cette période de 3 ans bXterra réparera ou remplacera sous réserve des conditions et restrictions complètes de la garantie limitée du produit disponible sur notre site Web bXterra agira à son gré comme seul recours en cas de violation de s...

Reviews: