1.5 How safety instructions are displayed
In this document safety instructions precede any sequence of actions
that could cause harm to persons or damage to property. All hazard
prevention measures must be followed. Safety instructions are dis-
played as follows:
SIGNAL WORD!
Source of hazard
(e.g. electric shock)
Type of hazard
(e.g. risk of fatal injury)!
► Escape or prevent hazard
► Rescue measure (optional)
Signal word / colour
Indicates the severity of the hazard
Warning symbol
Calls attention to the hazard
Source / type of hazard Indicates the type and the source of the
hazard
Consequences
Explains the consequences of not following
the safety instructions
Hazard prevention
measure
Explains how to avoid the hazard
Signal word Colour Severity of the hazard
DANGER
High-risk hazard.
Indicates a hazardous situation which, if not avo-
ided, will result in death or serious injury.
WARNING
Hazard with a moderate degree of risk.
Indicates a hazardous situation which, if not avoi-
ded, could result in death or serious injury.
CAUTION
Low-risk hazard.
Indicates a hazardous situation which, if not avoi-
ded, may result in minor or moderate injury.
1.6 Product-specific safety instructions
DANGER!
Mains voltage!
Risk of death by electric shock!
► Unplug device before any service and repair
work.
► If the mains cable of the unit becomes dama-
ged, you must replace it with an original BWT
cable.
Microbiological and sensory quality of the (partially) softened water
The quality of the treated water depends greatly on the conditions under which the unit is installed an operated. The most important factors are
listed in the following table.
When determining whether there is a problem with the sensory or microbiological quality of the treated water, it is important where in the system
the quality is measured. For example, if the quality is measured at the tap, the water quality may be affected by the pipe material or by the pre-
sence of a water heater or hot water storage tank.
1.7 Important notes
The unit must be installed as described in the installati-
on guide in compliance with the general requirements for
the supply of water in Germany [“AVB Wasser”] V, sec-
tion 12.2 by a water supply company or by a party re-
gistered in the water supply company’s index of fitters.
In keeping with TrinkwV § 16 and § 21 (German drinking water ordi-
nance), notify residents of the installation of the water softener, explain
how it works and which regenerative is used.
Using treated drinking water with plants and aquatic animals
Each species of plant and aquatic animal requires water that contains
a special combination of substances. Users of the unit should therefo-
re consult the standard literature and check that they can use retreated
drinking water for watering plants or for filling ornamental lakes, aqua-
riums or fish ponds.
The control unit in your product contains a long-lasting battery.
Do not dispose of single-use or rechargeable batteries in household
waste.
You must bring batteries to a designated collection point or send them
to BWT (free of charge). Used batteries contain valuable raw materials
that can be recycled.
Unfavourable conditions
BWT recommendations
Inflow water quality
Borderline inflow water quality, which can be-
come even worse within the unit
Contact your installer
Shorter maintenance intervals
Operating conditions
Long stagnation times and
infrequent regeneration
Observe the notes in the operating instructions
Salt quality
Cheap regenerative salts with high proportions
of insoluble components
Use regenerative in accordance with DIN EN 973
type A
Installation situation and
conditions
High ambient temperatures, e.g. near a hea-
ting unit
Drainage system for regeneration water incor-
rectly designed
Summary of Contents for Rondomat Duo-DVGW 10