Filtration pump mode
Manual mode: Allows the filtration pump to be stopped and started via
a menu. The 'Status' line shows whether the pump is ON or OFF. To
change the status, descend using the DOWN key and press the Plus/
Minus key, then press OK.
Automatic mode (with timer):
In this mode, filtration will run during the daily programmed windows (up
to 3 filtration windows; T1, T2 and T3), that will be repeated on every
day of the year.
1. Use the Up/ Down keys to select a window, each window is defined
by a filtration start and stop time.
2. Using the Up/Down arrows set the start hour
3. Press the Up key to access the minutes field and adjust this value
using the Up/Down keys.
4. Press OK to save these values or Back/Escape to cancel.
In the same way, set the stop time for the selected window.
See the section describing cleaning of the filter below.
Nota Bene 1: Auto mode will only be available if the pump is slaved to the Chlorine generator.
See chapter 4.3, Wiring
Smart mode
This mode is based on the automatic mode, with the three filtration windows,
however the filtration time will be adjsuted accirding to the pool water
temperature. Two temperature set points are defined.
The maximum temperature, above which the filtration time will be determined
by the programmed filtration windows, and the minimum temperature, below
which filtration will be reduced to 5 minutes, the minimum operation time.
Between these two temperatures, the filtration time icreases linearly. Use the
plus/minus keys to select the minimum and maximum temperatures.
The Anti-Freeze mode can be activated, this starts filtration when the water
temperature drops below 2 °C. To set the activate/deactivate windows for this
mode (possible to programme up to 3 windows), follow the instructions set
out in the paragraph Automatic Mode.
N.B. : SMART mode will only be available if the option “Use the temperature
sensor and/ or Heating is activated in the “Installer” menu.
Summary of Contents for PRO A
Page 56: ...2021 03 Indice de r vision B Code 29740 TRAITEMENT DE L EAU 56 88...
Page 86: ...Notes 2021 03 Indice de r vision B Code 29740 TRAITEMENT DE L EAU 86 88...
Page 87: ...Notes 2021 03 Indice de r vision B Code 29740 TRAITEMENT DE L EAU 87 88...
Page 88: ...2021 03 Indice de r vision B Code 29740 TRAITEMENT DE L EAU 88 88...