1.
time display mode (12 or 24 hour clock)
2.
hours
3.
minutes
4.
day of the week
To change the value of a blinking parameter, press the UP or DOWN arrow keys until the desired value is
displayed on the screen.
Then press the MENU key: the selected value is saved and the next parameter blinks for confirmation or
modification and so on, until the day of the week.
Upon validating the day of the week, all the time settings are saved and the screen returns to the default
display.
5.5
Alarm sub-menu
The SP 800 controller allows the user to set 9 weekly alarms that are triggered at the same time and on
the same day each week.
Upon accessing the "User alarm" sub-menu, the following screen is displayed :
ALARMS
(▼) (ESC) (▲)
- - - -
Press the UP arrow to set alarm 1, the following screen is displayed :
1. ALARM 1
DAY : [- - - - - - -]
- - - -
Alarm 1
Day [xxxxxxx]
Select a 7 character (each character representing a day of the week) combination from the 16 available
settings for each of the alarms. :
[- - - - - - -] : alarm inactive
[MTWTFSS] : alarm active each day of the week
[M - - - - - -] : alarm active on Monday only
[- T - - - - -] : alarm active on Tuesday only
…
[- - - - - - S : alarm active on Sunday only
[MTWTF - -] : alarm active from Monday to Friday inclusive
[- - - - - SS] : alarm active Saturdays and Sundays (Week-end)
[MTWTFS -] : alarm active from Monday to Saturday inclusive
[MTW - - - -] : alarm active from Monday to Wednesday inclusive
39/48
2020/10 - Indice de révision : D - Code : 38050