![BWT PERMAQ COMPACT 51 Installation And Operating Manual Download Page 16](http://html1.mh-extra.com/html/bwt/permaq-compact-51/permaq-compact-51_installation-and-operating-manual_2836822016.webp)
UK
16
10.2
Technical data
BWT PERMAQ
®
Compact 51
Capacity, l/h*
160
Max recovery, %
40-75
Salt retention, %
>98
Conductivity, µS/cm
<20
Reservoir, l
50
Electrical connection, V
230
Power consumption, kW
1.5
Electricity frequency, Hz
50
Pipe inlet,
diameter, "
½”
Concentrate outlet,
diameter, ”
10mm.
hose
Permeate outlet,
diameter, ”
¾"
Height, mm
750
Depth, mm
560
Width, mm
350
Max. water temp.,
C
25
Max. water pressure, bar
7
Min. water pressure, bar
2
Weight (full), kg
103
No. of membranes
1
* At drinking water quality 10°C, 3 bar, max. 500 mg/l total salt content.