7
If the temp. is below 10 °C, the
capacity will be 3 % below nor-
mal capacity for every degree
under 10 °C.
If e.g. the raw-water temp. is 8
°C, for an BWT PERMAQ
®
Com-
pact it means that the permeate
capacity is 6 % below the normal
400 l/h, i.e. 376 l/h. At the same
time make sure that the pressure
on the manometer (E-Figure 3)
does not exceed 12 bar + inlet
pressure from the water supply,
however maximum 15 bar.
The normal pressure indicated on
the manometer in order to obtain
normal permeate capacity will be
approx. 13.5-14.5 bar.
When the requested pressure and
permeate capacities have been
obtained, check again if the outlet
amount has been adjusted cor-
rectly.
(We recommend that you loosen
both lock nuts while the valves are
fine-adjusted).
When both valves have been
adjusted, they shall be locked
with the lock nuts. Please take
care not to move the valve when
you tighten the lock nut
NB! When the valves have been
locked, the plant shall be started
and stopped 4-5 times, and then
the flow shall be checked again;
the valves are re-adjusted if nec-
essary.
Now check that the quality of the
treated water on the permeate
hose (A-Figure 3); the conductivity
shall be below 20 µS/cm (con-
ductivity meter is available as
accessory). If the water quality is
below 20µS/cm it is OK and the
hose can be led back to the hole
in the reservoir tank.
The 270 litre reservoir tank now
will be filled up with treated water
<20 µS/cm.
Write the operating data in the
enclosed operating journal (see
section – 13.5 Operating jour-
nal).
7.3
Dearation of transport
pump
The transport pump (G-Figure 3)
is controlled by a pressure switch
and hydrophore is preset to 2.7
bar from our factory, so they do
not have to be adjusted.
Note! The transport pump (G-
Figure 3) will not start until the
reservoir tank has been complete-
ly full. Wait for the reservoir tank
to fill up completely (approx. 20
minutes). Check that the level
switch (H-Figure 3) automatically
stops the plant when the reservoir
tank is full.
NB: Do not touch the level
switch.
Create a large consumption of
treated water to get the air out of
the pump.
Check that the transport pump (G-
Figure 3) starts up automatically.
Check that the pump supplies
water and pressure.
When you have checked the
transport pump and found it to be
in order, close for consumption of
treated water.
Wait for the transport pump to
stop automatically.
Note! The transport pump does
not stop until 20/30 seconds after
the consumption has ceased due
to the built-in delay in the control
box.
Once again create a consumption
of treated water and this time let
the transport pump (G-Figure 3)
empty approx. 100 litres of the
reservoir tank content. Check if
the plant starts up automatically
and produces treated water. This
can be read on the flow meter (F-
Figure 3).
The plant is now commissioned
and ready for use.
7.4
Use of by-pass
Furthermore the plant is furnished
with a manual by-pass for raw
water, i.e. if the plant for some
reason experiences disturbances,
this valve can be opened and you
will have raw water on the outlet
for consumption. IMPORTANT!
When the plant is restarted, you
must remember to close the by-
pass valve again, otherwise you
will get a mixture of permeate
and raw water on the outlet.
8.
AUTOMATIC FUNCTIONS
The BWT PERMAQ
®
Compact
plant is equipped with a control
box which has following built-in
control functions:
Level switch for start/stop
of high-pressure pump
Indication of low water
level
and
stop
of
transport pump
Solenoid valve controls
raw water inlet
Pressure
switch
for
start/stop transport pump
(Stop 4.0 bar, Start 3.0
bar)
Alarm will go off when
raw water pressure drops
below 0.5 bar for more
than 2 min
Alarm will go off if
transportpump has been
running for more than 20
min
Stop of pump is delayed
by 20/30 seconds.
Extra level switch, alarm
high level (Option).
Alarm condictions and
DIP-switch - se section
9.2.10 and 9.2.11.
Summary of Contents for PERMAQ COMPACT 270 Series
Page 1: ...BWT PERMAQ COMPACT 271 274 Reverse Osmosis Plant Installation and Operating manual UK ...
Page 2: ...UK 2 ...
Page 10: ...UK 10 9 2 3 Alarm Low raw water pressure 9 2 4 Alarm Transport pump ...
Page 11: ...UK 11 9 2 5 Indication Level low 9 2 6 Alarm Level high ...
Page 12: ...UK 12 9 2 7 The plant is not operating ...
Page 20: ...UK 20 13 1 P I Diagram ...
Page 21: ...UK 21 13 2 Layout Drawings ...
Page 22: ...UK 22 ...
Page 23: ...UK 23 ...
Page 24: ...UK 24 ...
Page 25: ...UK 25 13 3 Wiring Diagram ...
Page 26: ...UK 26 ...
Page 27: ...UK 27 ...