10.2
Technical data:
BWT PERMAQ
®
Compact 270
SERIES
271
272
273
274
Capacity, l/h*
110
220
310
400
Maximum water recovery, %
40-75
40-75
40-75
40-75
Salt retention, %
>98
>98
>98
>98
Conductivity, µS/cm
<20
<20
<20
<20
Reservoir, l
270
270
270
270
Power connection, V
230
230
230
230
Power consumption, kW
1.5
1.5
1.5
1.5
Electrical frequency, Hz
50
50
50
50
Pipe inlet, diameter, "
½”
½”
½”
½”
Concentrate outlet, diameter, mm
10mm
Hose
10mm
hose
10mm
hose
10mm
hose
Permeate outlet, diameter, ”
¾"
¾"
¾"
¾"
Height, mm
1350
1350
1350
1350
Width, mm
630
630
630
630
Depth, mm
580
580
580
580
Maximum water temp.,
C
25
C
25
C
25
C
25
C
Maximum water pressure, bar
7 bar
7 bar
7 bar
7 bar
Minimum water pressure, bar
2 bar
2 bar
2 bar
2 bar
Weight (full), kg
330 kg
332 kg
334 kg
336 kg
Number of membranes
1
2
3
4
* At drinking water quality 10
C, 3 bar, max. 500 mg/l total salt content.
Summary of Contents for PERMAQ COMPACT 270 Series
Page 1: ...BWT PERMAQ COMPACT 271 274 Reverse Osmosis Plant Installation and Operating manual UK ...
Page 2: ...UK 2 ...
Page 10: ...UK 10 9 2 3 Alarm Low raw water pressure 9 2 4 Alarm Transport pump ...
Page 11: ...UK 11 9 2 5 Indication Level low 9 2 6 Alarm Level high ...
Page 12: ...UK 12 9 2 7 The plant is not operating ...
Page 20: ...UK 20 13 1 P I Diagram ...
Page 21: ...UK 21 13 2 Layout Drawings ...
Page 22: ...UK 22 ...
Page 23: ...UK 23 ...
Page 24: ...UK 24 ...
Page 25: ...UK 25 13 3 Wiring Diagram ...
Page 26: ...UK 26 ...
Page 27: ...UK 27 ...