BWT Liff Powermag PM100S Installation & Operating Instruction Manual Download Page 3

 
 

 

1. General Notes 

 

Powermag  is  a  WRAS  approved  electromagnetic  physical  water 
conditioner  that  utilises  a  powerful  electromagnetic  field  to  inhibit  hard 
crystalline scale formation in hot and cold water systems. The Powermag 
induces a specific magnetic field within the water path that has a physical 
effect  on  the  hardness  minerals  within  the  water  supply.  This  helps  to 
inhibit new formations and remove existing formations of scale, providing 
an environmentally friendly method of scale treatment without the use of 
chemicals. 

The  Powermag  physical  water  conditioner  alters  the  structure  of  scale 
forming  particles  encouraging  them  to  pass  through  the  pipe  system 
without leaving deposits of hard scale within the system. The Powermag 
physical  water  conditioner  does  not  introduce  sodium,  or  any  other 
chemicals, into the water and therefore the water remains potable. 

Physically conditioned water will tend to revert back to its untreated state 
over  time;  we  recommend  the  sooner  that  the  water  is  used  after 
treatment,  the  more  effective  the  physical  water  conditioner  will  be.  In 
addition  consideration  should  be  given  where  water  turbulence  may  be 
induced  in  the  water  flow  as  this  may  reduce  the  effectiveness  of  the 
physical water conditioner. Please refer to the installation section of this 
manual for guidance on the optimum position for treatment of the water 
supply. 

The  Powermag  does  not  require  a  separate  drain.  It  can  be  installed 
directly  in-line  without  the  need  for  water  bypass.  There  are  no  moving 
parts so the device requires minimal servicing. 

 

 

Summary of Contents for Liff Powermag PM100S

Page 1: ...Installation Operating Instruction Manual...

Page 2: ...2 Contents 1 General Notes 3 2 Installation 4 3 Electrical Notes 7 4 Troubleshooting Guide 9 5 Spare Parts List 9 6 Specifications 10 7 Warranty Information 11...

Page 3: ...g deposits of hard scale within the system The Powermag physical water conditioner does not introduce sodium or any other chemicals into the water and therefore the water remains potable Physically co...

Page 4: ...ows and fittings in order to adequately locate the device we recommend keeping this to a minimum The device is manufactured from stainless steel tubing and as such is resistant to corrosion We recomme...

Page 5: ...om a central water tank After a booster pump Directly on the cold mains supply where all outlets are mains fed Isolation Valve Isolation Valve Isolation Valve Pump Powermag Pipe Supports Water Tank Is...

Page 6: ...activity LED will run left to right when active LED will halt when inactive LED will illuminate fully when a fault is present Isolation Valve Isolation Valve LED Display Activity LED Display Isolation...

Page 7: ...l Notes Identifying the main components Control PCB Display Power Supply PCB Assembly inc smoothing capacitor and bridge rectifier MCB Coil DC Supply MCB Mains AC Supply Power Transformer Connection T...

Page 8: ...marked use brown cable use blue cable E use green yellow cable NOTE a spare Earth terminal is available on the left of the terminal block Connect thermistor cable to 2 central terminals marked TEMP or...

Page 9: ...ntrol PCB Display Mains MCB tripping Fault on transformer Test and replace transformer Coil DC supply MCB tripping Fault on coil Test and replace coil Panel temperature high Loose connections on power...

Page 10: ...30 Frictional loss bar 0 2 0 2 0 2 0 2 0 2 0 2 Max water temperature C 25 25 25 25 25 25 Max pressure bar 16 16 16 16 16 16 Electrical Specification NOTE MCB ratings are maximum safety ratings Actual...

Page 11: ...which it was not designed or intended Incorrect installation e g failure to follow instructions or advice given by BWT UK or its representatives and failure to follow industry guidelines or standard p...