Preparing the brine
●
Check that the unit has been properly installed.
●
Remove cover (
4
).
●
Pour regenerative into the storage area (
5
).
Recommended salt:
Cube or pellet salt is
recommended. This type of salt is high puri-
ty evaporated crystals, formed and pressed
into briquets. It has less than 1 % insolu
-
ble (not dissolvable in water) impurities.
●
Fill up the brine cavity (
6
) with about 4 litres (Be-
wamat 25 A) or 15 litres (Bewamat 75 A) with
drinking water.
Note:
Observe the following if consumption of a
large quantity of softened water is expected
after start-up: The unit requires about three
hours for the brine to form.
●
Insert mains plug.
Water supply must remain closed.
The display shows
StArt
and then alternates
between the remaining supply of softened water
and the day of the week (1-7) / time.
● Allow basic fixing to finish (about 40 sec.).
The running noise stops.
●
For automatic regeneration, press the OK but-
ton to interrupt.
●
Open the water supply.
● Initiating a start-up flush
●
Press and hold Change Mode but-
ton until
Ibn
appears in the display.
Flushing occurs for 1 minute (flush time t1). The
valve then moves into operating position.
●
The unit is ready for operation.
The capacity and the blending valve are preset. A
readjustment is only necessary for especially hard
water (hardness greater than 22 °d) or for water of
medium hardness (less than 14 °d).
e.g.
StArt
4450 L
6
10:50
Ibn
4
5