background image

PRODUCT INFORMATION 

BULLETIN 

 

 

 

105 Bonnie Drive 
Butler, PA 16002 
724-283-4681 
724-283-5939 (fax) 
www.bwieagle.com

 

 
 
 
 

 

 

 

AIR-EAGLE

®

 SR PLUS  

2.4 GHz  RF Transmitter 

MODEL 36-1200-BAT 

 
 

DESCRIPTION

 

 
The A

IR

-E

AGLE 

SR

 

PLUS

 

TX is an R.F. transmitter designed to send a 

single stop command to an Air-Eagle SR Receiver from up to 600 feet 
away. Any number of transmitters and receivers can be combined to 
create a medium-range remote control system that operates 
hazardous or hard-to-reach electrical apparatus from safe, convenient 
locations. This unit has eight user-selectable network frequencies to 
allow multiple systems to operate simultaneously in the same area 
without interference.   

 

INSTALLATION 

 
DISCONNECT Power from all equipment before installation. 
 
1. 

Mount the transmitter in a convenient location.  

2. 

Install antenna onto antenna connector located on the right side on 
the enclosure.  

3. 

Install the two AA lithium batteries that were provided. 

 

TERMINAL STRIP WIRING 

 

10 

E

-S

to

B

ut

to

 P

re

-

W

ire

to

 In

pu

t 1

 

C

 In

pu

t 2

 

In

pu

t 2

 

C

 In

pu

t 3

 

In

pu

t 3

 

C

 In

pu

t 4

 

In

pu

t 4

 

N

ot

 U

se

N

ot

 U

se

 

Dimensions (with mounting plate)  6.3” L  x  4.8” W  x 4.3” H 

 

CONTROLS & INDICATORS 

TX LED 

Illuminates red while booting up, then 
extinguishes. Illuminates red while any 
contact input is closed and unit is 
transmitting. When this LED blinks briefly 
following a transmission, the battery needs 
to be replaced. 

STOP Pushbutton 

Transmits CH1 RF “STOP” code to receiver 

Inputs 2, 3 and 4 

Independently transmit CH2, CH3 and CH4 
codes to receiver 

 
 

FREQUENCY SET-UP 

 

The unit is shipped from the factory with all SEL2 switches in the open 
positions. By default, it is operating on Frequency #1. If you wish to 
change the frequency, follow the instructions on the table below. 

 
 

1)  Remove power from unit and take cover off. 
2)  Select desired frequency using table below. 
3)  Reattach cover and apply power. Programming is now complete.  

FREQUENCY SET-UP 

SEL1 

(SW1-3) 

Network 
Frequency 

SW1 

SW2 

SW3 

(default)

 

OPEN 

OPEN 

OPEN 

CLOSED  

OPEN 

OPEN 

OPEN 

CLOSED 

OPEN 

CLOSED  

CLOSED 

OPEN 

OPEN 

OPEN 

CLOSED 

CLOSED 

OPEN 

CLOSED 

OPEN 

CLOSED 

CLOSED 

Note – SW4 not used 

 

 