BVME4000/6000
68
Copyright
1993,1995,1998,2001 BVM Ltd.
Appendix E Thermal Management
BVME4000
25
°
C
50
°
C
70
°
C
25MHz
MC68EC/LC040
No Heatsink
No Airflow
No Heatsink
No Airflow
No Heatsink
0.5m/s Airflow
33MHz
MC68EC/LC040
No Heatsink
No Airflow
No Heatsink
Natural Airflow
No Heatsink
0.5m/s Airflow
25MHz
MC68040
No Heatsink
No Airflow
No Heatsink
Natural Airflow
No Heatsink
0.5m/s Airflow
33MHz
MC68040
No Heatsink
Natural Airflow
No Heatsink
0.5m/s Airflow
Heatsink
1.0m/s Airflow
BVME6000
25
°
C
50
°
C
70
°
C
50MHz
MC68EC/LC060
No Heatsink
No Airflow
No Heatsink
No Airflow
No Heatsink
0.5m/s Airflow
66MHz
MC68EC/LC060
No Heatsink
No Airflow
No Heatsink
0.5m/s Airflow
No Heatsink
1.0m/s Airflow
50MHz
MC68060
No Heatsink
No Airflow
No Heatsink
Natural Airflow
No Heatsink
0.5m/s Airflow
66MHz
MC68060
No Heatsink
Natural Airflow
No Heatsink
0.5m/s Airflow
No Heatsink
1.0m/s Airflow
NOTES:
Temperatures shown above are for ambient air temperature.
If operation above 50
°
C for extended periods is anticipated, then it is recommended that
the airflow is doubled, or (where not already specified) a heatsink is fitted.
Where a heatsink is specified, fit AAVID part 3325 24 B 0 0032.