Appendix E
AC Motor Drive Settings
Page C-13
Buskro Ltd.
BK7IB-2
C.3.10 Group 9: Communication Parameters
Table C-10:
Parameters
Functions
Settings
Buskro
Setting
9-00
Communication address
1 ~ 247
1
9-01
Transmission speed
0: Baud rate 4800
1: Baud rate 9600
2: Baud rate 19200
1
9-02
Transmission fault
treatment
0: Warn and continue running
1: Warn and ramp to stop
2: Warn and coasting stop
3: No warn and keep running
0
9-03
Modbus communication
watchdog timer
0: Disable
1 ~ 20: 1 ~ 20 Sec
0
ASCII
mode
0: 7,N,2
1: 7,E,1
2: 7,0,1
3: 8,N,2
4: 8,E,1
5: 8,0,1
9-04
Communication
protocol
RTU
mode
6: 8,N,2
7: 8,E,1
8: 8,0,1
0