![BUSKRO BK7IB-2 User Manual Download Page 94](http://html.mh-extra.com/html/buskro/bk7ib-2/bk7ib-2_user-manual_2835654094.webp)
Appendix E
AC Motor Drive Settings
Page C-10
Buskro Ltd.
BK7IB-2
C.3.7 Group 6: Protection Parameters
Table C-7:
Parameters
Functions
Settings
Buskro
Setting
6-00
Over-Voltage
Prevention Level
0: disable
350 ~ 410V
390
6-01
Over-current
Prevention Level
0: disable
20 ~ 200%
170
6-02
Over-torque
detection
0: disable
1: enable during constant speed operation and
continues until the continuous limit is reached.
2: enabled during constant speed operation and
halted after detection.
3: enabled during accel and continues before
continuous output time limit is reached.
4: enabled during accel and halted after over-torque
detection.
0
6-03
Over-torque
detection level
30 ~ 200%
150
6-04
Over-torque
detection time
0.1 ~ 10.0 Sec
0.1
6-05
Electronic thermal
overload relay
0: Not used
1: Act with standard motor
2: Act with special motor
0
6-06
Electronic thermal
characteristic
30 ~ 600 Sec
60
6-07
Present fault record 0: No fault occurred
6-08
Second most recent
fault record
1: oc (over current)
2: ov (over voltage)
6-09
Third most recent
fault record
3: oH (over heat)
4: oL (over load)
6-10
Forth most recent
fault record
5: oL 1 (electronic thermal)
6: EF (external fault)
6-11
Fifth most recent
fault record
7: Reserved
8: Reserved
6-12
Sixth most recent
fault record
9: ocA (current exceed during acceleration)
10: ocd (current exceed during deceleration)
11: ocn (current exceed during steady state)
0
Summary of Contents for BK7IB-2
Page 1: ...BK7IB 2 Inline Base Part No 9105171 User s Guide V1 0 ...
Page 5: ...General Information Buskro Ltd BK7IB Inline Base Chapter 1 1 0 General Information ...
Page 13: ...Operator Instructions Buskro Ltd BK7IB Inline Base Chapter 2 2 0 Operator Instructions ...
Page 22: ...BK7IB 2 Integration Buskro Ltd BK7IB Inline Base Chapter 3 3 0 BK7IB Integration ...
Page 25: ...Electrical System Buskro Ltd BK7IB Inline Base Chapter 4 4 0 Electrical System ...