Parameter
Settings
(
Bold
=default)
Description
Set Clock
(Set)
Press
OK
and use the
UP/DOWN
keys (to
change the setting) and
LEFT/RIGHT
keys (
to move to the next field) to set the hour
(24-
hr format only, “00”=midnight, “12”=noon)
and
minute, and then (on the lower row), the year,
month and date.
Field Scan
On, Off
(After On is
selected):
“A”
Start/Stop, “B”
Start/Stop,
Interval
Turns Field Scan (Time Lapse) recording
mode on/off. When activated, Field Scan
forces the camera to take photos or videos
even when it is not triggered by a nearby
live animal, useful for constant monitoring
of an area that might be far away from the
camera. The user can set the start and stop
times for up to two independent “blocks” of
Field Scan recording, as well as the interval
time between each photo/video. To ensure
correct operation, avoid setting overlapping
start/stop times for Field Scan A and B.
Please read the “Field Scan 2x…” section of
this manual for details on using this feature.
NOTE: If the "Camera Mode" parameter is
set to "Day" or "Night" operation only, that
will take priority over your Field Scan set-
tings. Set Camera Mode to "24HR" if you are
setting day and night Field Scan start and/
or stop times.