Daily
•
Check filter indication gauge for the condition
of the return filter. Dial reading should be in
the green zone. Filter must be replaced if out
of the green zone.
Annually
• Drain tank into clean container and check
inside of tank for signs of rust or moisture.
• Check the magnetic Drain Plug for iron con-
tamination.
• If the contaminants exist inside of the tank
(metal shavings, etc) dispose of the oil in a
environmentally safe manner.
• Clean the inside of any loose scale
• Inspect the suction screen through
the access panel, for rips or holes,
clean if necessary.
•
Change Return Line Filter:
•
Ikron SP010
or equivalent
• Clean Tank Breather.
• Apply a small bead of silicon gasket
on the top tank flange and replace top
lid
•
Refill with hydraulic oil :
•
Kendal 4 Seasons AW32
or
equivalent
•
PTO Shaft
– grease every 10 hours.
Pull apart and apply grease to the
sliding members. Grease the yoke
bearings at this time as well. Use multi
purpose grease.
Filter indication gauge on power pack
Return
Line Filter
Access Panel
Suction Screen
Magnetic Drain Plug
Power Pack Maintenance