Product Description | 2
0870572240_RA0400-0630C_Ex_-0011_IM_en
7 / 40
2.3 Start Controls
The machine comes without start controls. The control of the machine is to be provided
in the course of installation.
The machine can be optionally equipped with a starter unit or a variable-frequency drive.
2.4 Accessories
NOTE
Depending on the ATEX classification of the machine, some of the following accessories
may be mandatory, see
ATEX Classifications and Associated Accessories [
.
2.4.1 Gas Ballast Valve
The gas ballast valve mixes the process gas with a limited quantity of ambient air to
counteract the condensation of vapour inside the machine.
The gas ballast valve has an influence on the ultimate pressure of the machine, see
2.4.2 Inlet Filter
The inlet filter protects the machine against dust and other solids in the process gas. The
inlet filter is available with a polyester (antistatic) cartridge.
2.4.3 Water-oil Heat Exchanger
In case of unfavourable ambient conditions a water-oil heat exchanger can be provided.
See
Cooling Water Connection (Optional) [
2.4.4 Temperature Switch
The temperature switch monitors the gas and the oil temperature of the machine.
The machine must be stopped when the gas and/or the oil reach a certain temperature,
see
Wiring Diagram Temperature Switch [
2.4.5 Resistance Thermometer
The resistance thermometer monitors the gas temperature of the machine and optionally
the oil temperature.
Warning and trip signals must be set, see
Wiring Diagram Resistance Thermometer
.
2.4.6 Level Switch
The level switch monitors the oil level.
The machine must be stopped when the oil level is too low.
2.4.7 Pressure Switch
The pressure switch monitors the pressure in the oil separator.
The machine must be stopped when the gas reaches a certain pressure, see