Decommissioning | 9
0870572240_RA0400-0630C_Ex_-0011_IM_en
31 / 40
9
Decommissioning
• Shut down the machine and lock against inadvertent start up.
• Vent the connected lines to atmospheric pressure.
Version with water-oil heat exchanger:
• Turn off the water supply.
• Disconnect the water supply.
• Open the water bypass valve (WBV).
• Blow through the water cooling inlet with compressed air.
• Disconnect all connections.
If the machine is going to be stored:
• See
9.1 Dismantling and Disposal
• Drain the oil.
• Remove the exhaust filters.
• Remove the oil filter.
• Separate special waste from the machine.
• Dispose of special waste in compliance with applicable regulations.
• Dispose of the machine as scrap metal.
10 Spare Parts
NOTICE
Use of non-Busch genuine spare parts.
Risk of premature failure!
Loss of efficiency and ATEX compliance!
• The exclusive use of Busch genuine spare parts and consumables is recommended for
the correct functioning of the machine and to validate the warranty.
Spare parts kit
Description
Part no.
Service kit
(RA/RC 0400 / 0502 /
0630 C)
Includes all the necessary parts for mainten-
ance.
for ATEX classification type “A”
0992 543 533 +
0532 541 197
Service kit
(RA/RC 0400 / 0502 /
0630 C)
Includes all the necessary parts for mainten-
ance.
for ATEX classification type “B”, “C” or
“E”
0992 543 533
Service kit
(RA/RC 0400 / 0502 /
0630 C)
Includes all the necessary parts for mainten-
ance.
for ATEX classification type “D”
0992 568 271 +
0532 541 197
See
ATEX Classifications and Associated Accessories [
tion of the machine.
If other parts are required:
• Contact your Busch representative for the detailed spare parts list.