2 | Product Description
6 / 28
0870572700_RD0200-0360A_-0003_IM_en
2.5 Optional Accessories
2.5.1 Increased Flow Gas Ballast Valve
It increases the flow of the standard gas ballast valve to deal with high water vapour
load.
2.5.2 Inlet Filter
The inlet filter protects the machine against dust and other solids in the process gas. The
inlet filter is available with a paper or polyester cartridge.
The clamped design makes it easy to adjust the position to the installation and the o-ring
sealing guaranties the tightness.
2.5.3 Cooling Air Deflector
It allows the cooled air from the heat exchanger (AHE) to be evacuated from the bottom
of the machine.
2.5.4 Water-oil Heat Exchanger
In case of unfavourable ambient conditions a water-oil heat exchanger can be provided.
See
Cooling Water Connection (Optional) [
2.5.5 Temperature Switch
The temperature switch monitors the oil temperature of the machine.
Depending on the oil type, the machine must be stopped when the oil reaches a certain
temperature, see
.
2.5.6 Level and Temperature Switch
The level switch with integrated temperature switch monitors the oil level and the oil
temperature. It has one level switch point and two temperature switch points.
The machine must be stopped when the oil level is too low or, depending on the oil
type, when the oil reaches a certain temperature, see