Installation | 5
Instruction Manual PUMA WP 0250-2000 D_EN_en
11 | 36
5.2.3
Discharge Connection
NOTICE
Discharge gas flow obstructed.
Risk of damage to the machine!
●
Make sure that the discharged gas will flow without obstruction. Do not shut off or throttle the
discharge line or use it as a pressurized air source.
Connection size(s):
– DN63, DIN 28404 for WP 0250-0500 D
– DN100, DIN 28404 for WP 0700 D
– DN160, DIN 28404 for WP 1000-2000 D
Depending on the specific configuration ordered, other connection dimensions may apply.
5.2.4
Cooling Water Connection
Only required for PUMA WP 1000 D4 and WP 2000 D2 versions.
2 x CWC
2 x CWC
Description
CWC
Cooling water connections
2 connections on each side (cooling water inlet and outlet)
●
Connect the cooling water connections (CWI / CWO) to the water supply.
Connection size:
– G1/4 (CWC)