5 | Installation
10 | 36
Instruction Manual PANDA WZ 0250-0500 B_EN_en
5.2.1
Gas Flow Variants
The machine can be installed in different ways:
1
2
Description
1
Vertical gas flow
2
Lateral discharge (Optional)
5.2.2
Suction Connection
WARNING
Unprotected suction connection.
Risk of severe injury!
●
Do not put hand or fingers in the suction connection.
NOTICE
Ingress of foreign objects or liquids.
Risk of damage to the machine!
If the inlet gas contains dust or other foreign solid particles:
●
Install a suitable filter (5 micron or less) upstream from the machine.
Connection size(s):
– DN100, DIN 28404 for WZ 0250, 0500 B
Depending on the specific configuration ordered, other connection dimensions may apply.
5.2.3
Discharge Connection
NOTICE
Discharge gas flow obstructed.
Risk of damage to the machine!
●
Make sure that the discharged gas will flow without obstruction. Do not shut off or throttle the
discharge line or use it as a pressurized air source.