Page 1: ...Get technical data instruction manuals service kits PANDA Vacuum Boosters WV 4500 B Instruction Manual 0870559397 A0005_en US Original instructions 6 9 2022...

Page 2: ...itting the Coupling 13 6 Electrical Connection 14 6 1 Machine delivered without Control Box or Variable Speed Drive VSD 14 6 2 Wiring Diagram Three Phase Motor 15 7 Commissioning 17 7 1 Compression Ch...

Page 3: ...state of the art methods Nevertheless residual risks may remain as described in the following chapters and in accordance with the chapter Intended Use 5 This instruction manual highlights potential h...

Page 4: ...UT OFP EB EB Description IN Suction connection MTB Motor terminal box OUT Discharge connection OFP Oil fill plug MP Magnetic plug OSG Oil sight glass NP Nameplate ODP Oil drain plug BPV Bypass valve B...

Page 5: ...outside the intended use of the machine Risk of injuries Risk of damages to the machine Risk of damages to the environment Make sure to follow all instructions described in this manual The machine is...

Page 6: ...gases with the machine component materials Risk of corrosion inside the compression chamber which can reduce performance and its lifetime Check if the process gases are compatible with those followin...

Page 7: ...machine is already filled with oil Tilting a machine that is already filled with oil can cause large quantities of oil to ingress into the cylinder Drain the oil prior to every transport or always ho...

Page 8: ...apertures with adhesive tape or reuse provided caps If the machine is to be stored for more than 3 months Wrap the machine in a corrosion inhibiting film Store the machine indoors dry dust free and if...

Page 9: ...any other way Make sure that the oil sight glass OSG remains easily visible Make sure that enough space remains for maintenance work Make sure that the machine is placed or mounted horizontally a max...

Page 10: ...l a suitable filter 5 micron or less upstream from the machine Connection size s DN250 DIN 28404 Depending on the specific configuration ordered other connection dimensions may apply 5 2 2 Discharge C...

Page 11: ...N_en 11 36 5 3 Filling Oil NOTICE Use of an inappropriate oil Risk of premature failure Loss of efficiency Only use an oil type which has previously been approved and recommended by Busch For oil type...

Page 12: ...en the oil filling is achieved Write down the oil change date on the sticker Last oil change __ __ ____ Oil type see nameplate Change interval see instruction manual If there is no sticker part no 056...

Page 13: ...WV 4500 B ROTEX 26 In case of a machine delivery without motor Fit the second coupling hub on the motor shaft separately delivered Axially adjust the hub in such a way until value E is reached When t...

Page 14: ...ot be affected by electric or electro magnetic disturbance from the mains if necessary seek advice from Busch Make sure that the EMC of the machine is compliant with the requirements of your supply ne...

Page 15: ...the motor Busch recommends installing a D curve circuit breaker Connect the protective earth conductor Electrically connect the motor NOTICE Incorrect connection Risk of damage to the motor The wiring...

Page 16: ...Manual PANDA WV 4500 B_EN_en Double star connection multi voltage motor with 12 pins low voltage 4 4 4 Star connection multi voltage motor with 12 pins high voltage 4 4 4 Delta connection multi voltag...

Page 17: ...on chamber Risk of damage to the machine Do not lubricate the compression chamber of the machine with oil or grease Make sure that the installation conditions see Installation Conditions 9 are met Swi...

Page 18: ...s flow outlet OUT 3 Barrier gas connections BGC 4 Barrier gas connections BGC Connection size 4 x G3 8 BGC Barrier gas requirements Gas type Dry nitrogen air or other suitable gas Gas temperature C 0...

Page 19: ...o any action requiring touching the machine let the machine cool down first CAUTION Failing to properly maintain the machine Risk of injuries Risk of premature failure and loss of efficiency Maintenan...

Page 20: ...ours Change the oil of the gear and bearing housings both sides see Oil Change 21 Every 6 months Perform an oil inspection change it if the oil has changed its initial color see Oil Color Inspection 2...

Page 21: ...n consult your Busch representative in order to find out why this color change has occurred 8 4 Oil Change NOTICE Use of an inappropriate oil Risk of premature failure Loss of efficiency Only use an o...

Page 22: ...8 Maintenance 22 36 Instruction Manual PANDA WV 4500 B_EN_en For oil type and oil capacity see Technical Data 29 and Oil 30...

Page 23: ...n the oil filling is achieved Write down the oil change date on the sticker Last oil change __ __ ____ Oil type see nameplate Change interval see instruction manual If there is no sticker part no 0565...

Page 24: ...dismantling of the machine that goes beyond anything that is described in this manual should be done by Busch authorized technicians In case of the machine having conveyed gas that was contaminated wi...

Page 25: ...t the machine cool down first Shut down the machine and lock against inadvertent start up Disconnect the power supply Vent the connected lines to atmospheric pressure Disconnect all connections If the...

Page 26: ...of premature failure Loss of efficiency The exclusive use of Busch genuine spare parts and consumables is recommended for the correct functioning of the machine and to validate the warranty There is...

Page 27: ...eign matter or repair the machine contact Busch Equip the machine with a mesh screen at the suction connection The motor is defective Replace the motor The machine does not reach the usual pressure Su...

Page 28: ...s at the inlet too high Observe the permitted gas inlet temperature see Technical Data 29 Oil level too low Top up oil The backing pump is not correctly defined Contact Busch The oil is black Oil chan...

Page 29: ...l motor speed min 1 3000 3600 Sound pressure level dB A 67 70 Uncertainty KpA dB 3 Ambient temperature range C 5 40 Max gas inlet temperature C 200 P 10 hPa staging ratio of 4 Relative humidity at 30...

Page 30: ...100 ISO VG 100 100 Ambient temperature range C 0 40 0 40 Part number 1 L packaging 0831 168 356 0831 122 573 Part number 5 L packaging 0831 168 357 0831 122 572 Remark Food applications H1 To know wh...

Page 31: ...ctrical and electronic equipment incl all related applicable amendments and comply ies with the following designated standards that have been used to fulfill those provisions Standards Title of the St...

Page 32: ...certain hazardous substances in Electrical and Electronic Equipment Regulations 2021 and comply ies with the following designated standards that have been used to fulfill those provisions Standards T...

Page 33: ...Instruction Manual PANDA WV 4500 B_EN_en 33 36 Notes...

Page 34: ...34 36 Instruction Manual PANDA WV 4500 B_EN_en...

Page 35: ...Instruction Manual PANDA WV 4500 B_EN_en 35 36...

Page 36: ...sence In every country highly competent local personnel delivers custom tailored support backed by a global network of expertise Wherever you are Whatever your business We are there for you Local repr...