Transport | 3
0870159870_MV1202A_A0003_IM_en_MD
7 / 28
2.5 Optional Accessories
2.5.1 Inlet Filter
The inlet filter protects the machine against dust and other solids in the process gas.
The inlet filter is available with a paper or polyester cartridge.
2.5.2 Vacuum Relief Valve
The ultimate pressure is limited by a vacuum relief valve. The vacuum relief valve is
adjusted ex-works to the minimum permitted ultimate pressure (see nameplate).
3
Transport
WARNING
Suspended load.
Risk of severe injury!
• Do not walk, stand or work under suspended loads.
WARNING
Lifting the machine using the motor eye bolt.
Risk of severe injury!
• Do not lift the machine using the eye bolt fitted to the motor. Only lift the machine as
shown.
• Make sure that the eyebolt(s) (EB) is/are in faultless condition, fully screwed in and
tightened by hand.
SCH
Mink
B
U
Use both eye bolts!
Machine weight:
see the technical data or the nameplate (NP)
• Check the machine for transport damage.
If the machine is secured to a base plate:
• Remove the machine from the base plate.
• Mount the rubber feet, delivered loose, to the machine's base frame.