11 | Troubleshooting
22 / 28
0870159870_MV1202A_A0003_IM_en_MD
11 Troubleshooting
DANGER
Live wires.
Risk of electrical shock.
• Electrical installation work must only be executed by qualified personnel.
CAUTION
Hot surface.
Risk of burns!
• Prior to any action requiring touching the machine, let the machine cool down first.
SCH
Mink
B
U
VRE
IS
CPL
Problem
Possible Cause
Remedy
The machine does not start. The motor is not supplied
with the correct voltage.
• Check the power supply.
The motor is defective.
• Replace the motor.
The coupling (CPL) is defect-
ive.
• Replace the coupling (CPL).
The machine does not
reach the usual pressure on
the suction connection.
The inlet screen (IS) is par-
tially clogged.
• Clean the inlet screen
(IS).
The vacuum relief valve
(VRE) is misadjusted or de-
fective.
• Replace the vacuum re-
lief valve (VRE)
The inlet filter cartridge (op-
tional) is partially clogged.
• Replace the inlet filter
cartridge.
Internal parts are worn or
damaged.
• Repair the machine (con-
tact Busch).
The machine runs very nois-
ily.
Worn coupling (CPL).
• Replace the coupling (CPL).
Oil level too low.
• Top up oil.
Defective bearings.
• Repair the machine (con-
tact Busch).