Maintenance | 7
Instruction Manual MINK MV 0500-0600 B_EN_en
25 | 40
7
Maintenance
WARNING
Machines contaminated with hazardous material.
Risk of poisoning!
Risk of infection!
If the machine is contaminated with hazardous material:
●
Wear appropriate personal protective equipment.
CAUTION
Hot surface.
Risk of burns!
●
Prior to any action requiring touching the machine, let the machine cool down first.
NOTICE
Using inappropriate cleaners.
Risk of removing safety stickers and protective paint!
●
Do not use incompatible solvents to clean the machine.
CAUTION
Failing to properly maintain the machine.
Risk of injuries!
Risk of premature failure and loss of efficiency!
●
Maintenance work must only be executed by qualified personnel.
●
Respect the maintenance intervals or ask your Busch representative for service.
●
Shut down the machine and lock against inadvertent start up.
●
Vent the connected lines to atmospheric pressure.
If necessary:
●
Disconnect all connections.
7.1
Maintenance Schedule
The maintenance intervals depend very much on the individual operating conditions. The intervals
given below are considered as starting values which should be shortened or extended as
appropriate. Particularly harsh applications or heavy duty operation, such as high dust loads in the
environment or in the process gas, other contamination or ingress of process material, can make it
necessary to shorten the maintenance intervals significantly.