7 | Parameter Overview
24 / 56
0870166596_MV0040-0080C-D_PCI_A0004_IM_de_MD
Code Parameter
Min.
Max.
Unit Default ID
Description
P11.1 ProcessDataOut 1 selec-
tion
0
12
0
852
Variable mapped on PD1:
0 = Output current
1 = Motor speed
2 = Motor current
3 = Motor voltage
4 = Motor torque
5 = Motor power
6 = DC-link voltage
7 = Active fault code
8 = Analogue AI1
9 = Analogue AI2
10 = Digital input state
11 = PID feedback value
12 = PID set point
P11.2 ProcessDataOut 2
selection
0
16
1
853
Variable mapped on PD2.
See P11.1
P11.3 ProcessDataOut 3
selection
0
16
2
854
Variable mapped on PD3.
See P11.1
P11.4 ProcessDataOut 4
selection
0
16
4
855
Variable mapped on PD4.
See P11.1
P11.5 ProcessDataOut 5
selection
0
16
5
856
Variable mapped on PD5.
See P11.1
P11.6 ProcessDataOut 6
selection
0
16
3
857
Variable mapped on PD6.
See P11.1
P11.7 ProcessDataOut 7
selection
0
16
6
858
Variable mapped on PD7.
See P11.1
P11.8 ProcessDataOut 8
selection
0
16
7
859
Variable mapped on PD8.
See P11.1
P11.9 FB Aux CW selection
0
5
0
1821 PDI for Aux CW:
0 = Not used
1 = PDI1
2 = PDI2
3 = PDI3
4 = PDI4
5 = PDI5
P11.1
0
FB PID set point
selection
0
5
1
1822 PDI for PID set point.
See P11.9
P11.1
1
FB PID actual selection
0
5
2
1823 PDI for PID feedback
See P11.9
P11.1
2
FB AnalogueOutCntrl
selection
0
5
3
1824 PDI for AnalogueOutCntrl
See P11.9