5 | Installation
10 | 44
Instruction Manual MINK MB 0018 A_EN_en
●
Make sure that the installation space or location is vented such that sufficient cooling of the ma-
chine is provided.
●
We strongly recommend to install the product at the top level of the fluid circuit to avoid the stag-
nation of condensates inside the compression stage.
●
Make sure that all provided covers, guards, hoods, etc. are mounted.
WARNING
Vibration level.
Risk of premature failure!
●
Make sure the product is protected from external shocks. Regarding vibration level, please con-
tact your Busch representative to discuss the corresponding levels.
If the machine is installed at an altitude greater than 1000 meters above sea level:
●
Contact your Busch representative, the motor should be derated or the ambient temperature
limited.
5.2
Connecting Lines / Pipes
WARNING
Unprotected connection.
Risk of severe injury!
●
Do not put hand or fingers in the connection.
●
Remove all protective covers before installation.
●
Make sure that the connection lines cause no stress on the machine‘s connection; if necessary use
flexible joints.
●
Make sure that the line size of the connection lines over the entire length is at least as large as
the connections of the machine.
●
Make sure that no dust or other particles can enter into the machine.
In case of long connection lines it is advisable to use larger line sizes in order to avoid a loss of effi-
ciency. Seek advice from your Busch representative.
●
Make sure that the connections are “face sealed” and not “thread sealed” to ensure tightness.