Accessories | 11
Instruction Manual FOSSA FO 0015 A - FO 0035 B_EN_en
19 / 28
11 Accessories
Accessory
Part No.
Inlet filter
0530 566 434
Exhaust Filter
0562 566 435
Gas ballast adapter
0916 566 457
Gas ballast valve
0540 559 847
Kit of wheels
0999 569 268
12 Troubleshooting
Problem
Possible Cause
Remedy
The machine does not start. The motor is not supplied
with the correct voltage.
• Check the power supply.
Internal parts are worn or
damaged
• Repair the machine
(contact Busch).
The fuse has blown.
• Check the electrical
installation.
• Replace the fuse.
The motor is defective.
• Repair the machine
(contact Busch).
The machine does not reach
the usual pressure on the
suction connection.
The inlet screen is partially
clogged.
• Clean the inlet screen.
The inlet filter cartridge (op-
tional) is partially clogged.
• Replace the inlet filter car-
tridge.
Measurement method or
reading is false.
• Check gauge, check final
pressure without
installation connected.
Leak in the system.
• Repair leak.
Worn tip seal.
• Replace tip seal, see
Seal and Non-return
Valve Replacement
[
.
Internal parts are worn or
damaged.
• Repair the machine
(contact Busch).
The machine runs very noisi-
ly.
The machine runs too hot.
• See problem “The ma-
chine runs too hot”.
Internal parts are worn or
damaged.
• Repair the machine
(contact Busch).
The machine runs too hot.
Insufficient cooling.
• Check the ventilation.
Ambient temperature too
high.
• Observe the permitted
ambient temperature.
The machine is contaminat-
ed by process residuals.
• Repair the machine
(contact Busch).
Discharge pipe obstructed.
• Check the discharge line.
The motor is defective.
• Repair the machine
(contact Busch).