Storage | 4
0870237638_LR0110-0580A_-_IM_en
9 / 32
• The lifting point of a bare shaft pump is shown above.
• Check the machine for transport damage.
4
Storage
NOTICE
Storage temperature below +5°C.
Risk of damage to the machine!
• Drain the operating liquid from the machine and the system before storage.
• Or add an anti-freeze solution.
After testing, all Busch Dolphin vacuum pumps are vented and drained.
4.1 Short Term (Up to 3 Months)
• Seal all apertures with adhesive tape or provided caps.
If possible:
• Store the machine indoors, dry, dust free and if possible in original packaging
preferably at temperatures b5 … 55 °C.
4.2 Medium Term (3 Months to 6 Months)
• Remove the shaft coupling guard (if not supplied as a bare shaft machine).
• Rotate the machine shaft by hand weekly to prevent bearing indentation.
• Leave the shaft at approximately 90 degrees to the original position, using a tempor-
ary mark on the shaft to assist.
• Replace the coupling guard, taking care to align correctly and ensure that all fasteners
are replaced and fully tightened.
• Where shaft seal is gland packing, loosen the packing gland plate.
4.3 Long Term (Over 6 Months)
If the machine is constructed in cast iron material:
• Preserve internals by using a combined VPI (Vapour Phase Inhibitor) and Contact In-
hibitor Oil at a recommended concentration of 1 litre per m
3
to prevent the machine
from corroding. Ensure all apertures are sealed after application.
• Remove the shaft coupling guard (if not supplied as a bare shaft machine).
• Rotate the machine shaft by hand weekly to prevent bearing indentation.
• Leave the shaft at approximately 90 degrees to the original position, using a tempor-
ary mark on the shaft to assist.
• Coat the exposed shaft ends and shaft coupling with wax preservative or heavy
grease.
• Replace the coupling guard, taking care to align correctly and ensure that all fasteners
are replaced and fully tightened.