background image

Installation and 

Operating Instructions 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vacuum Pumps 

 

Dolphin LM 0100-0800 A, LT 0130-0750 A 

 

 

 

 

 

Busch GVT Ltd. 

Unit A Westmere Drive Crewe 

CW1 6ZD 

England 

 

0870700034 /

 171101 / Original instructions / Modifications reserved

 

Summary of Contents for Dolphin LM 0100-0800 A

Page 1: ...lation and Operating Instructions Vacuum Pumps Dolphin LM 0100 0800 A LT 0130 0750 A Busch GVT Ltd Unit A Westmere Drive Crewe CW1 6ZD England 0870700034 171101 Original instructions Modifications res...

Page 2: ...6 Months 11 Every Year 11 Overhaul 12 Removal from Service 12 Temporary Removal from Service 12 Recommissioning 12 Dismantling and Disposal 12 Spare Parts 13 Troubleshooting 14 EU Declaration of Conf...

Page 3: ...position the liquid ring touches the hub of the impeller h As the impeller rotates clockwise view from drive end the liquid ring moves away from the hub making space for gas to be drawn in through th...

Page 4: ...re tagged with one of the keywords DANGER WARNING and CAUTION as follows Noise Emission For the sound pressure level in free field according to EN ISO 2151 page 24 Technical Data Transport Transport w...

Page 5: ...is carried out such that the essential safety requirements of the Machine Directive 2006 42 EC are complied with in the responsibility of the designer of the machinery into which the vacuum pump is to...

Page 6: ...of clean operating liquid which is normally water The operating liquid enters the Vacuum pump Compressor Vacuum and pressure pump through a connection J on the housing and is discharged from the Vacuu...

Page 7: ...perating liquid is recirculated from the separator tank to the vacuum pump The remainder is discharged from the separator and transferred to the drain as waste The fresh liquid F is introduced in suff...

Page 8: ...e the vacuum pump shall be maintained after shutdown of the vacuum pump Provide a manual or automatic operated valve non return valve in the suction line Make sure that the suction line does not conta...

Page 9: ...e not covered or obstructed and that the cooling air flow is not affected adversely in any other way Filling the Operating Liquid The handling of the operating liquid supply system is not subject to t...

Page 10: ...e vacuum pump see above comment If operating speed is varied from the given values the flow rate requirements vary accordingly Operating Liquid Level Note The options to check the level depend on the...

Page 11: ...pipe work for leakage Check the mechanical seals for leakage This will be observed at the tell tale holes in the bearing housings Replace seals and bearings if signs of leakage Make sure that the vacu...

Page 12: ...the manufacture of the vacuum pump involve no risk Dispose of the vacuum pump as scrap metal DANGER In case the vacuum pump conveyed gas that was contaminated with foreign materials which are dangero...

Page 13: ...USA Busch LLC 516 B Viking Drive Virginia Beach VA 23452 Tel 1 800 USA PUMP 872 7867 Your point of contact for service and spare parts in Canada Busch Vacuum Technics Inc 1740 Boulevard Lionel Bertran...

Page 14: ...eter Use larger diameter Internal parts are worn or damaged Repair the vacuum pump Busch service The gas conveyed by the vacuum pump smells displeasing Process components evaporating under vacuum Chec...

Page 15: ...all drive motor coils are properly connected The drive motor operates on two phases only Check the proper connection of the wires against the connection diagram Tighten or replace loose connections Th...

Page 16: ...t temperature too high Observe the permitted ambient temperatures Temperature of the inlet gas too high Observe the permitted temperatures for the inlet gas Insufficient gas transfer Introduce a suita...

Page 17: ...agnetic Compatibility 2014 30 EU Motors LVD 2014 35 EU RoHS 2011 65 EU restriction of the use of certain hazardous substances in electrical and electronic equipment and following the standards Standar...

Page 18: ...8 60 5 5 1750 180 71 LM 0270 A 50 5 5 1450 220 70 68 157 1 8 60 7 5 1750 267 71 LM 0530 A 50 11 1450 440 72 164 317 3 60 15 1750 556 73 LM 0800 A 50 18 5 1450 722 75 178 340 3 8 60 22 1750 867 76 LT 0...

Page 19: ...LM 0100 0800 A LT 0130 0750 A 0870700034 171101 page 19...

Page 20: ...0 e mail sales busch ie Israel Busch Israel Ltd 1 Mevo Sivan Street Qiryat Gat 82022 Israel Tel 972 0 8 6810485 Fax 972 0 8 6810486 e mail service_sales busch co il Italy Busch Italia S r l Via Ettore...

Reviews: