Electrical Connection | 6
Instruction Manual COBRA BA 0100 C_EN_en
15 | 36
6
Electrical Connection
DANGER
Live wires.
Risk of electrical shock.
●
Electrical installation work must only be executed by qualified personnel.
CURRENT PROTECTION OF THE CUSTOMER INSTALLATION:
DANGER
Missing current protection.
Risk of electrical shock.
●
Current protection according to EN 60204-1 must be insured by the customer on its installation.
●
The electrical installation must comply with the applicable national and international standards.
NOTICE
Electromagnetic compatibility.
●
Make sure that the motor of the machine will not be affected by electric or electro- magnetic dis-
turbance from the mains, if necessary seek advice from Busch.
●
Make sure that the EMC of the machine is compliant with the requirements of your supply net-
work system, if necessary provide further interference suppression (EMC of the machine, see EU
Declaration of Conformity [
33] or UK Declaration of Conformity [
34]).
●
Wire the mating connector (delivered loose) in accordance with the scheme below:
Mains connection (MC) - 4-pin connector
1
2
3
4
Description
1
Phase 1 (L1)
2
Phase 2 (L2)
3
Phase 3 (L3)
4
Earth