5 | Installation
14 / 44
Instruction Manual COBRA NC 2500 B WCV_EN_en
5.2.4 Barrier Gas System Connection
Without nitrogen panel
PRV
FR
BGC
MAN
FME
BGC
Barrier gas connection
FME
Flow meter
FR
Flow regulator
MAN
Manometer
PRV
Pressure regulating valve
• Connect the barrier gas connection (BGC) to the gas supply.
Connection size:
– G1/4, ISO 228-1
• Make sure that the gas complies with the following requirements:
Gas type
Dry nitrogen or air
Gas temperature
°C
0 ... 60
Maximum gas pressure
bar
13
Recommended pressure setting at the
pressure regulating valve (PRV)
bar
3
Filtration
µm
5
Recommended flow rate
SLM*
30
Air quality (only for air)
Acc. to ISO
8573-1
Class 5.4.4.
* standard litre per minute
5.3 Filling Oil
NOTICE
Use of an inappropriate oil.
Risk of premature failure!
Loss of efficiency!
• Only use an oil type which has previously been approved and recommended by
Busch.