Installation | 5
0870203597_NC0100-0300B_WCV_Ex_-0001_IM_en
17 / 60
5
Installation
5.1 Installation Conditions
WARNING
The installation conditions are not respected in an ATEX environment.
Risk of severe injury!
Risk of explosion!
• Take care that the installation conditions are met.
NOTICE
Use of the machine outside of the permitted installation conditions.
Risk of premature failure!
Loss of efficiency!
• Take care that the installation conditions are fully complied with.
• Make sure that the environment of the machine complies with the ATEX classification
of the machine according to the data given on the nameplate of the motor and the
nameplate of the machine (NP).
• Make sure that the ambient conditions comply with the
• Make sure that the environmental conditions comply with the protection class of the
motor and the electrical instruments.
• Make sure that the installation space or location is vented such that sufficient cooling
of the machine is provided.
• Make sure that cooling air inlets and outlets of the motor fan are not covered or ob-
structed and that the cooling air flow is not affected adversely in any other way.
• Make sure that the oil sight glass (OSG) remains easily visible.
• Make sure that enough space remains for maintenance work.
• Make sure that the machine is placed or mounted horizontally, a maximum of 1° in
any direction is acceptable.
.
If the machine is equipped with a plate heat exchanger (PHE):
• Check the cooling liquid level, see
Cooling Liquid Level Inspection [
.
• Make sure that the cooling water complies with the requirements, see
.
If the machine is installed at an altitude greater than 1000 meters above sea level:
• Contact your Busch representative, the motor should be derated or the ambient
temperature limited.
If additional electrical components not included in scope of delivery should be added:
• Make sure that they have a better or equal ATEX classification than that of the
machine, see the ATEX marking on the nameplate (NP).
For classification type “E” and “H” (see
ATEX Classifications and Associated Accessor-
):
• Make sure that the installation space or location is ventilated enough in order to
prevent the formation of an explosive area.
Summary of Contents for COBRA ATEX NC 0100-0300 B
Page 58: ...Note ...