233
T-Modell - 17/18 - Ausgabe 09/17 - 2891569 - BUE-0029-19EN
Troubleshooting
14
14.6
Heater/boiler
In the event of a defect contact the nearest customer service workshop of the
relevant appliance manufacturer. The list of addresses is enclosed with the
accompanying appliance documentation. Only authorised qualified personnel
may repair the appliance.
14.6.1
Truma heater/boiler with CP plus digital operating unit
Fault
Cause
Remedy
Heater does not ignite
Temperature sensor on
operating unit or remote
sensor defective
Pull out plug on operating
unit. The heater then
works without thermostat.
Contact the customer
service as soon as
possible
No display on the operat-
ing unit
Fuse on the transformer/
rectifier is defective
Replace fuse on the
transformer/rectifier
Fuse in the electronic
control unit has been
triggered
Contact customer service
Living area battery defec-
tive
Charge or replace the liv-
ing area battery (or have
it charged or replaced)
Fault with error code is
displayed
See table "Fault search
instruction"
See table "Fault search
instruction"
Boiler empties, safety/
drainage valve has
opened
Internal temperature
below 8 °C
Heat inside
Safety/drainage valve
cannot be closed
Temperature at safety/
drainage valve below
8 °C
Heat inside
Fan wheel runs noisily or
not steadily
Fan wheel is soiled
Contact Truma service
department
Summary of Contents for Ixeo Time IT 590
Page 2: ...T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Instruction manual ...
Page 10: ...10 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Introduction 1 ...
Page 56: ...56 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Pitching the motorhome 5 ...
Page 118: ...118 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Gas system 7 ...
Page 184: ...184 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Appliances 9 ...
Page 248: ...248 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Special equipment 15 ...
Page 262: ...262 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Helpful notes 17 ...