146
T-Modell - 17/18 - Ausgabe 09/17 - 2891569 - BUE-0029-19EN
Appliances
9
9.2
Heater and boiler
The heater can both heat up the vehicle interior (heating the room air) and heat
up the domestic water (boiler function). The following instructions are also
valid if the heater is only used as boiler.
Initial start-up
When lighting the heater for the first time a small amount of smoke and odour
will occur. Immediately set the operating switch of the heater to its highest
position. Open doors and windows and ventilate well. Smoke and odour will
disappear by themselves after a while.
9.2.1
Models with waste gas vent on the right-hand side of the
vehicle
X
Never let gas escape unburned due to danger of explosion.
X
Never run the heater in gas operation when refuelling, on ferries or in the
garage. Danger of explosion!
X
Never operate the heater in gas operation in closed spaces (e.g.
garages). Danger of poisoning and suffocation!
X
The waste gas vent may neither be closed nor blocked.
X
Do not use the space behind the heater as a storage compartment.
X
The water in the boiler can be heated up to 65 °C. Risk of scalding!
Z
Never use boiler when empty.
Z
If the boiler is not being used, empty it if there is any risk of frost.
Z
Only operate the boiler with the maximum temperature setting if you
require a large quantity of warm water. This protects the boiler against the
build-up of limescale.
Z
The circulation fan is automatically switched on when the hot-air heater is
activated, and it stays on. This drains the living area battery when the
vehicle is not connected to an external 230 V power supply. Take into con-
sideration that the living area battery only has limited reserves of energy.
Z
Do not use the water from the boiler as drinking water.
Z
The hot-air heater can even run on an empty boiler.
Z
If the power supply to the heater was interrupted, the time must be reset.
X
If the awning is put up and the heater is running in gas operation,
exhaust gases from the heater can escape into the awning area. Danger
of suffocation! Make sure the area is sufficiently ventilated.
Summary of Contents for Ixeo Time IT 590
Page 2: ...T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Instruction manual ...
Page 10: ...10 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Introduction 1 ...
Page 56: ...56 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Pitching the motorhome 5 ...
Page 118: ...118 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Gas system 7 ...
Page 184: ...184 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Appliances 9 ...
Page 248: ...248 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Special equipment 15 ...
Page 262: ...262 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Helpful notes 17 ...