6.1.18 EtherNet/IP settings (option)
Note:
The "EtherNet/IP" menu (M77) only exists if your DIGIFORCE
®
9311 is installed with option
Vxxx4.
Diagram 30: EtherNet/IP settings
Parameters in the "EtherNet/IP" menu (M77)
SW-version
Firmware version of the EtherNet/IP Fieldbus module
Serial number
Serial number of the Fieldbus module
Control via
EtherNet/IP
: the DIGIFORCE
®
9311 responds solely to control signals
(inputs) from the EtherNet/IP interface.
PLC
: the DIGIFORCE
®
9311 responds solely to control signals (inputs)
from the PLC I/O interface.
When control via PLC I/O is selected, data is still transferred on the
EtherNet/IP real-time channel.
MAC address
Address for identifying the Fieldbus module in the EtherNet/IP network.
IP configuration
Network configuration type (BOOTP, DHCP, static)
Please note
: this parameter cannot be changed in the DIGIFORCE
®
9311.
IP address
IP address
If BOOTP or DHCP is selected for "IP Configuration", the IP address is
assigned by a BOOTP or DHCP server.
Please note
: the IP address cannot be changed by the user if BOOTP or
DHCP is selected for the IP configuration mode.