7
Tap AutoSize to display the entire
measurement curve including all the
graphical evaluation elements.
8
Tap to return to the "Graphical test operation" menu.
6.3.5.2 Graphical test operation – AutoSet
Once you have recorded a measurement curve in measurement mode or in the "Graphical test operation"
menu (M59), the DIGIFORCE
®
9311 displays the
[AutoSet]
button, which can be used to place
automatically two "Window" graphical evaluation elements. This AutoSet function positions one "Window"
in the centre of the displacement range (X-range) and the other "Window" at the end of the forward curve
(end-point region). Then you simply need to set the entry and exit sides and make any fine adjustments
you require to the limits.
Diagram 61: Graphical test operation – AutoSet