26
of 175
6.3 PLC outputs - Transfer from slave to master
The data refers to the PLC output of the DIGIFORCE
9307. The data described here is the data
transferred from the DIGIFORCE
®
9307 to the PROFIBUS master.
The function of the PLC-In / PLC-Out bits is identical to the parallel PLC I/O ports on the unit itself and
can be found from the DIGIFORCE
®
9307 operation manual for the unit. Also the signal timing is
available within the DIGIFORCE
®
9307 operation manual.
6.3.1 PLC outputs Byte 1
PLC outputs Byte 1 (Slave
Master)
Valid values:
OUT_READY
Bit 0 LSB
OUT_ERROR
Bit 1
OUT_NOK_ONL1
Bit 2
OUT_NOK_ONL2
Bit 3
OUT_OK
Bit 4
OUT_NOK
Bit 5
OUT_S1
Bit 6
OUT_S2
Bit 7 MSB
6.3.2 PLC outputs Byte 2 (9307 adjustable outputs)
PLC outputs Byte 2 (Slave
Master)
Valid values:
PLC_OUT8
Bit 0 LSB
PLC_OUT7
Bit 1
PLC_OUT6
Bit 2
PLC_OUT5
Bit 3
PLC_OUT4
Bit 4
PLC_OUT3
Bit 5
PLC_OUT2
Bit 6
PLC_OUT1
Bit 7 MSB