FIR Filters are part of the digital process built in the DAC chip. These filter settings mainly affect high-frequency
roll-offs usually in the 18khz and above frequency range. The effect of the filter settings is very subtle and may
not always be audible.
Opamp Change & Upgrade
The Burson Conductor 3R allows opamp changing to customise its sound to the owner’s preference. When changing
opamps, please be aware of the following:
1.
The opamp power supply voltage in the Burson Conductor 3R is +/-15V. Always remove the power supply before
opening up the unit.
2.
There are 2 dual and 2 single opamps inside the Conductor 3R.
3.
Please refer to the following diagram for the position and correct orientation of the opamps. The notch at the
top of the opamp indicates the orientation of the opamp within the socket. Match it to the existing opamp.
4.
The case can be opened by removing 4 hex screws at the bottom of the case. Use the supplied hex key.