Type  ME24 

I/O-Module

Summary of Contents for ME24

Page 1: ...Quickstart English Deutsch Fran ais Type ME24 I O Module...

Page 2: ...he right to make technical changes without notice Technische nderungen vorbehalten Sous r serve de modifications techniques B rkert Werke GmbH Co KG 2016 2017 Operating Instructions 1705 0 _ 8 1_00810...

Page 3: ...TECHNICAL DATA 7 5 1 Conformity 7 5 2 Standards 7 5 3 Operating conditions 7 5 4 Mechanical data 7 5 5 Electrical data 8 6 INSTALLATION 9 6 1 Mount Type ME24 on backplane Type BEF1 9 6 2 Connect exter...

Page 4: ...ing instructions can be found on the Internet at www buerkert com 1 1 Definition of term In these instructions the term product always refers to the I O module Type ME24 1 2 Symbols DANGER Warns of an...

Page 5: ...components recommended and authorized by B rkert Use only when in perfect condition and always ensure proper storage transportation installation and operation Use only as intended 3 BASIC SAFETY INST...

Page 6: ...not touch electronic components while the supply voltage is switched on 4 GENERAL INFORMATION 4 1 Contact address Germany B rkert Fluid Control Systems Sales Center Christian B rkert Str 13 17 D 74653...

Page 7: ...formity with the EC Direc tives can be found on the EC Type Examination Certificate and or the EC Declaration of Conformity if applicable 5 3 Operating conditions WARNING Risk of injury Avoid heat sou...

Page 8: ...tput 4 20 mA Galvanic isolation Protection against DC reverse polarity Resolution 6 A Maximum loop impedance at current output 22 mA 1350 at 35 V DC 850 at 24 V DC 300 at 12 V DC Detection of open loo...

Page 9: ...0 5 2500 Hz Input impedance approx 3 5 k at voltage of 5 35 V Switching threshold VON 5 35 V VOFF 2 V DC Tab 3 Electrical properties 2AI 2DI 6 INSTALLATION WARNING Risk of injury from improper install...

Page 10: ...r cable Connection terminals Fig 3 Connect external sensors and actuators Unscrew fastening screw at the cover of Type ME24 hexagon socket 2 5 mm Open and remove cover Pull out connection terminals In...

Page 11: ...ircuit 1 20 30 V 2 A max OUTPUT no galvanic isolation 2 3 AO1 4 20 mA output galvanically isolated 4 AO1 4 20 mA output galvanically isolated 5 FE Shielding 6 AO2 4 20 mA output galvanically isolated...

Page 12: ...1 AO1 FE AO2 AO2 DO1 DO1 FE DO2 DO2 2AO 2DO f x 2 wire 2 3 4 5 6 7 8 9 10 11 12 Fig 5 External circuit 2AO 2DO f x 2 wire 0 V 20 30 V 20 30 V 0 V 20 30 V 20 30 V 0 V 0 V S S S S 1 Digital input on the...

Page 13: ...ation External circuit 1 20 30 V 2 A max total current no galvanic isolation 2 DO1 Open drain 3 20 30 V 2 A max total current no galvanic isolation 4 DO2 Open drain 5 20 30 V 2 A max total current no...

Page 14: ...put on the external instrument External load e g valve External load e g valve 4DO f x 1 2 3 4 5 6 7 8 9 DO1 DO2 DO3 DO4 FE Fig 8 External circuit 4DO PWM 20 kHz ME24 models 2AI 2DI 1 2 3 4 5 6 7 8 9...

Page 15: ...5 35 V OFF 2 V Input galvanically isolated 9 DI1 ON 5 35 V OFF 2 V Input galvanically isolated 10 FE Shielding 11 DI2 ON 5 35 V OFF 2 V Input galvanically isolated 12 DI2 ON 5 35 V OFF 2 V Input galva...