229
SAW sensor – Parameter
Type 8098 FLOWave L
15.13.4
Activating a user-defined damping of the values of the
acoustic transmission factor
The damping makes it possible to damp the fluctuations of the measured values of the acoustic trans
-
mission factor:
• on the display,
• on the totalizers,
• on the outputs. The damping set for an analog output comes in addition to the damping of the acoustic
transmission factor.
By default, the measured values of the acoustic transmission factor are damped with the level
None
.
To damp the fluctuations of the measured values, you can:
→
either choose 1 of the 3 predefined damping levels:
Low
,
Medium
or
High
. See chapter 15.13.3
→
Or you can set your own damping parameters with the
Special
damping.
With the
Special
damping, you can set 2 parameters:
•
a user-defined
Response time
in seconds,
• the
Jump threshold
, i.e. a user-defined percentage. If 2 consecutive measured values vary for ± the per
-
centage, no damping is applied to the second measured value.
To set your own damping parameters of the DF values, do the following:
→
Go to the
CONFIGURATION
view.
→
SAW sensor
→
Confirm to access the
Parameter
view.
→
Add. meas. values
→
Acoustic transmission factor
→
Damping
The
Current settings
are displayed
→
Special
→
Set the value of the
Response time
→
Choose if the
Jump threshold
is enabled or disabled
→
If the
Jump threshold
is enabled, set the value.
→
The
New settings
are displayed
Save.
The special damping of the values of the acoustic transmission factor is active.
English
Summary of Contents for Flowave 8098
Page 4: ...General contents 4 Type 8098 FLOWave L English...
Page 12: ...12 Type 8098 FLOWave L English...
Page 36: ...36 Technical data Type 8098 FLOWave L English...
Page 72: ...72 Type 8098 FLOWave L English...
Page 78: ...78 Commissioning Type 8098 FLOWave L English...
Page 96: ...96 Type 8098 FLOWave L English...
Page 144: ...144 Type 8098 FLOWave L English...
Page 248: ...248 Type 8098 FLOWave L English...
Page 286: ...286 SAW sensor Maintenance Type 8098 FLOWave L English...
Page 304: ...304 Type 8098 FLOWave L English...
Page 316: ...316 Type 8098 FLOWave L English...
Page 350: ...350 Spare parts and accessories Type 8098 FLOWave L English...
Page 352: ...352 Appendix Type 8098 FLOWave L English...
Page 353: ......
Page 354: ...www burkert com...