28
Pneumatic connection
Type 8653
10.4.2
Configuration area „General settings“
Menus
Description/
factory settings (if available)
Detailed view “parameter”
büS
Displayed name
Device name, can be changed without affecting communication.
Location
Device installation location, displayed with the device name.
Description
Free description text, is used for example in tooltips.
Advanced
Unique device name
Factory default number code .
Used for partner assignments and should therefore not be
changed!
Baud rate
50, 125, 250,
500
kbit/s or 1 Mbit/s
CANopen address
Entry of address/node ID.
If the address is already used, the device will switch to a different
address (only in büS mode).
Bus mode
CANopen,
büS
or standalone device
CANopen status
This menu is only displayed if “CANopen” is set as the bus mode.
Deallocation delay
0.5 s
Time between loss of a partner and deletion of its configuration.
Entry is possible, but usually does not need to be changed. This
value only has an effect if in büS mode.
Alarm limits
Supply voltage
Error high
26.4 v
Error low
21.6 v
Hysteresis
1.0 v
Device temperature
Error high
85°c
Error low
–20 °c
Hysteresis
2.0°c
Diagnostics
Switch complete diagnostics on or off
PDO Configuration
Enter the transmission times
PDO 1
10 ms
inhibit time
2s
event timer
Reset to default values
Reset PDO settings
Demo mode
Off
Special mode for trade fairs and presentations
Display
Display
Brightness
70 %
Contrast
50 %
Setup
Entry of base settings via a start-up wizard
english