Burkert 5281 Series Operating Instructions Download Page 3

Type 5281

Fluid Control Systems

Operating instructions

We reserve the right to make technical changes without
notice

 Bürkert Werke GmbH Co.  All rights reserved

Operating Instructions No. 803 312   01/99/02

BÜRKERT GERMANY

Chr.-Bürkert-Straße 13-17

Berlin

Ph: (0 30) 67 97 17 - 0

74653 Ingelfingen

Dortmund

Ph: (0 23 73) 96 81 - 0

Ph: (0 79 40) 10-0

Dresden

Ph: (03 59 52) 36 30 - 0

Fax (0 79 40) 10-204

Frankfurt

Ph: (0 61 03) 94 14 - 0

Hannover

Ph: (05 11) 9 02 76 - 0

München

Ph: (0 89) 82 92 28 - 0

Stuttgart

Ph: (07 11) 4 51 10 - 0

BÜRKERT INTERNATIONAL

A

Ph.

(01) 8 94 13 33

Fax

(01) 8 94 13 00

AUS

Ph.

(02) 96 74 61 66

Fax

(02) 96 74 61 67

B

Ph.

(03) 3 25 89 00

Fax

(03) 3 25 61 61

CDN

Ph.

(9 05) 8 47 55 66

Fax

(9 05) 8 47 90 06

CH

Ph.

(0 41) 7 85 66 66

Fax

(0 41) 7 85 66 33

CZ

Ph.

(06 41) 22 61 80

Fax

(06 41) 22 61 81

DK

Ph.

(0 44) 50 75 00

Fax

(0 44) 50 75 75

E

Ph.

(93) 3 71 08 58

Fax

(93) 3 71 77 44

ET

Ph.

(0 40) 54 27 38

Fax

(0 40) 54 41 65

F

Ph.

(01) 48 10 31 10

Fax

(01) 48 91 90 93

GB

Ph.

(0 14 53) 73 13 53

Fax

(0 14 53) 73 13 43

HKG

Ph.

24 80 12 02

Fax

24 18 19 45

I

Ph.

(02) 9 52 01 59

Fax

(02) 9 52 90 33

J

Ph.

(03) 32 47 34 11

Fax

(03) 32 47 34 72

KOR

Ph.

(02) 34 62 55 92

Fax

(02) 34 62 55 94

N

Ph.

(0 63) 84 44 10

Fax

(0 63) 84 44 55

MAL

Ph.

(04) 6 57 66 49

Fax

(04) 6 57 21 06

NL

Ph.

(0 34) 6 59 53 11

Fax

(0 34) 6 56 37 17

NZ

Ph.

(09) 5 70 25 39

Fax

(09) 5 70 25 73

P

Ph.

(01) 4 42 26 08

Fax

(01) 4 42 28 08

PL

Ph.

(0 22) 6 27 47 20

Fax

(0 22) 6 27 47 20

RC

Ph.

(02) 27 58 31 99

Fax

(02) 27 58 24 99

S

Ph.

(0 40) 66 45 100

Fax

(08) 7 24 60 22

SF

Ph.

(09) 5 49 70 600

Fax

(09) 5 03 12 75

SGP

Ph.

3 83 26 12

Fax

3 83 26 11

TR

Ph.

(02 32) 4 59 53 95

Fax

(02 32) 4 59 76 94

USA

Ph.

(9 49) 2 23 31 00

Fax

(9 49) 2 23 31 98

ZA

Ph.

(0 11) 3 97 29 00

Fax

(0 11) 3 97 44 28

DEAR CUSTOMER

Congratulations on your purchase of this Bürkert appliance. For your
own safety, please carefully read through these operating
instructions before installing the appliance. Your local Bürkert branch
will be pleased to answer any questions you may have.

CIRCUIT  FUNCTION

WW A

Type 5281

Coil Kits

Set of
Wearing
Parts Valve

Set of Wearing Parts
Pilot Control

ENGLISH

• When planning the application of the device, and during its operation,

observe the general technical rules!

• Take suitable measures to prevent unintentional operation or

impermissible impairment!

• Note that lines and valves must not be unscrewed from systems that

are under pressure!

• Always switch off the voltage supply before working on the system!
• If these instructions are ignored, no liability will be accepted from our

side, and the guarantee on the device and on accessories will also
become invalid!

• Warning! The surface of the electromagnet can become very hot

during continuous operation. Danger of injury!

To ensure that the device will function correctly, and have a
long service life, please comply with the information in these
Operating Instructions, as well as with the application condi-
tions and permissible data given in the Type 5281 data sheet:

Read the voltage, electrical power, type of protection and
current from the rating plate!
Voltage tolerance:  ±10%

• Electrical power connection: Instrument socket type 2508 to the tag

connections on the coil (protection class IP 65);
Tightening torque: 1 Nm

• When screwing down the instrument socket onto the coil, ensure that

the flat seal is well seated!

• With impulse coils, pay attention to asynchronous excitation!

Modular, servo-assisted flow valve with servo-diaphragm and
push-over coil

• coil can be locked in 4 x 90° steps, in between which it can be freely

positioned around the armature guide tube

• tightening torque of the fixing screws: max. 5 Nm
• can be mounted in any position, preferably with the magnetic system

at the top

• valve operation A: service port normally closed
• media: neutral fluids and gases which do not attack the valve body

and seal or diaphragm materials

• seal material: refer to rating plate following the nominal diameter

(NBR, EPDM,  FPM)

• permissible temperature range of the medium: -10 °C to 100 °C
• max. ambient temperature: + 55°
• the port connections are compatible with the previous model 281/291

Work on the valve should only be carried out by specialist staff
and with the correct tools!

• Clean the piping system before installing the valve!
• Where necessary, connect a strainer upstream to protect against

faults!

• Pay attention to the flow direction (direction of arrow).
• Seal the thread using PTFE tape!
• Ensure that there is the full diameter available at the inlets and outlets

to the valve, and that pilot channels are open!

• When tightening the pipe connections, never use the valve as a lever!
• Be careful of distortion when installing the valve body.
• Faults can be caused by soiling, short circuits and loss of power!
• Attention: Jammed coils can cause coil overheating with AC!
• In case of faults, check the port connections, voltages, type of current

and operational pressure!

Voltage

   Power

Order no.

     [V]

      [W]

024 / DC

8

126 434 R

024 / 56

8

645 556 D

110 / 56

8

645 557 E

230 / 56

8

645 558 P

024 / DC

8

126 434 R

024 / 56

8

645 556 D

120 / 60

8

643 802 B

240 / 60

8

643 803 C

024 / DC

8

126 434 R

024 / 56

8

645 556 D

100 / 56

8

645 559 Q

110 / 56

8

645 557 E

200 / 56

8

645 560 M

230 / 56

8

645 558 P

DN

Sealing material

Order no.

13 - 65

NBR

645 561 A

13 - 65

FPM

645 562 B

13 - 65

EPDM

645 563 C

13

NBR

624 012 J

13

FPM

624 013 K

13

EPDM

624 014 L

20

NBR

624 015 M

20

FPM

624 016 N

20

EPDM

624 017 P

25

NBR

624 018 Y

25

FPM

624 019 Z

25

EPDM

624 020 W

32, 40

NBR

624 021 K

32, 40

FPM

624 022 L

32, 40

EPDM

624 023 M

50

NBR

624 024 N

50

FPM

624 025 P

50

EPDM

624 026 Q

Valve

SPARE PARTS

Pilot Control

When ordering replacements parts, please also quote the order
number of your complete appliance in addition to the order
number of the replacement parts.

Coil kits Europe

Coil kits A.P.A.C.

Coil kits N.A.F.T.A.

Set of Wearing Parts

Reviews: