Technical specifications
Dimensions
96 x 64 x 23 mm
Battery
Lithium Battery 3V, CR123A
Number: 2
Service life:
over 70,000 locking cycles
Permissible temperature
0°– 40°C
(no formation of condesati-
on)
Number of possible codes
999.999
Code length
4 or 6
Programming
Freely selectable PIN
Fixed assigned PIN
Material
Zamac
Locking direction
L, R, LAD
Lock attachment
Mounting plate
Latch
Latch bolt (nickel-plated)
▪
If the configuration step is completed incorrectly, the
lock signals this with 8 consecutive flashes of the LED.
Caution: the lock is disabled for 45 seconds after 3 wrong
inputs. A red flash every second indicates that the lock is
currently disabled. This disablement can be terminated early
by entering the master code.
The master code must always be entered as follows:
√√ 1 master code √
(e. g. √√ 1 934 716 √)
Functional description
Freely selectable PIN mode
In this mode, the user can enter any PIN. The user must
first close the door. The user then enters a PIN of their
choice and engages the lock. The PIN entered is valid until
the lock is opened with the same PIN.
Fixed assigned PIN mode
In this mode, the PIN is stored in the lock. The lock only
engages or disengages when the stored PIN is entered. Up
to 50 PINs can be stored simultaneously. Each stored PIN
can open the lock, even if it has been locked with a different
PIN.
LED-locking status indicator
A red flash every second in the locking indicator indicates
that the lock is engaged. When open, the LED does not
flash. This function is optional and can be turned on or off
as desired.
Automatic locking
Automatic locking can only be activated in
fixed assigned
PIN
mode. When automatic locking is activated and a lock is
opened with a PIN, the lock automatically engages again
after 3 seconds. The trap function still enables the door to
be closed, although the knob can no longer be turned.
Code reenter
The code reenter can only be used in
freely selectable PIN
mode. If a PIN is entered to engage the lock, it must be
input again when the green LED flashes for a short time to
confirm. Only then does the lock actually engage. Simply
enter the code again to open.
Battery warning
The low battery warning is given in two stages. If the bat-
tery capacity drops below the first level, the LED lights up
red for three seconds after a PIN is entered. If the capacity
falls to a critical level, the lock cannot be engaged at all and
can only be opened with the master code.
Note: we recommend replacing the batteries as soon as the
red LED gives its first warning. If warnings are not heeded
and the batteries are completely drained, the lock can only
be opened using an emergency power supply. The
emergency power supply pack is available from us.
√√ 1 master code √
(e. g. √√ 1 934 716 √)
Master code
The master code starts off any programming process and
can re-enable a lock at any time. In freely selectable PIN
mode, the PIN used to close is deleted once the master
code has been entered.
The master code must always be entered as follows: