background image

a

b

c

g

d

e

f

h

i

j

k

QUADRO PS 7350

www.burg-waechter.de

0,5 – 32 m

0,5 – 32 m

m

2

/m

3

ft

2

/ft

3

precision

+1%

QUADRO

BURG-WÄCHTER KG 

Altenhofer Weg 15 
58300 Wetter 
Germany

ProfiScale QUADRO

Distance meter

en

 Operating instructions

Summary of Contents for QUADRO PS 7350

Page 1: ... e f h i j k QUADRO PS 7350 www burg waechter de 0 5 32m 0 5 32m m2 m3 ft2 ft3 precision 1 QUADRO BURG WÄCHTER KG Altenhofer Weg 15 58300 Wetter Germany ProfiScale QUADRO Distance meter en Operating instructions ...

Page 2: ...nsor Laser pointer light pointer Two row LCD display data on the top row displays the current reading The data on the bottom row displays the reading in the memory BASE key measurement basis selector button To switch off the device press this button for two seconds M button memory button MODE button conversion mode Three conversion modes length area volume default setting length measurement Press ...

Page 3: ...use overloading the device or incorrect storage as well as normal wear and defects that only have an insignificant effect on the value or usability of the device The warranty shall be immediately invalidated if unauthorized persons work on the device In the event that a warranty claim arises please hand over the entire device incl packaging description and batteries along with the sales receipt to...

Page 4: ...tion mode The symbol appears in the upper part of the display At the same time the previous reading appears in the lower part of the display Remark 1 The first time you press the button the initial data is added together in the lower part of the display and the data in the upper part is reset to 0 2 Press the READ button for the second measurement The reading is shown in the display Press the butt...

Page 5: ...tton twice in succession the addition function is cancelled and the symbol disappears from the display Briefly press the button to activate the addition function Briefly press the button twice to deactivate the function Step 3 Press the RM button to recall first area measured The M symbol disappears and the stored data is automatically deleted Step 4 Press the button again The sum of both areas ap...

Page 6: ...t is ft in Press the READ button again to return to the measurement status Important information troubleshooting Problem Behebung If you restart the device with a time delay of less than 5 seconds you see an incorrect display or no display when you press a button Remove and re insert the battery to access the original display Incorrect and inaccurate measurements the symbol appears continuously in...

Reviews: