Page 6
Tank Drain
1. Loosen screws that secure the front access panel. Remove the panel.
2. Tighten the white shutoff clamp on the long hose between the tank and inlet solenoid.
2. Disconnect the hose clamp and hose from the inlet solenoid.
3. Place the end of the drain hose in a container that has a minimum capacity of [3.5 gallons / 13.25 L Singles]
[6.0 gallons / 22.7 L-Twins].
4. Release the white clamp to drain water from the tank.
5. When tank is empty, replace the hose onto the inlet solenoid, and tighten the clamp.
6. Replace the front panel and tighten the screws.
PLUMBING REQUIREMENTS
These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi
(0.138 and 0.620 mPa) from a 1/2˝ or larger supply line. A shut-off valve should be installed in the line before
the brewer. Install a regulator in the line when pressure is greater than 90 psi (0.620 mPa) to reduce it to 50
psi (0.345 mPa). The water inlet fitting is .75-11.5 NH (HOSE THREAD). For convenience an elbow adaptor is
provided to convert to a 1/4˝ flare fitting (3/8˝ flare on twins & HV units). Bunn-O-Matic does not recommend
the use of a reverse-osmosis or deionized water supply to this equipment.
REQUIRED: 1.25 gpm (4.73 lpm)
flow rate from water supply line.
NOTE -
Bunn-O-Matic recommends 3⁄8" copper tubing for all installations from the 1⁄2" water supply line. A tight
coil of tubing in the water line will facilitate moving the brewer to clean the counter top. Bunn-O-Matic does not
recommend the use of a saddle valve to install the brewer. The size and shape of the hole made in the supply
line by this type of device may restrict water flow.
As directed in the International Plumbing Code of the International Code Council and the Food Code Manual
of the Food and Drug Administration (FDA), this equipment must be installed with adequate backflow
prevention to comply with federal, state and local codes. For models installed outside the U.S.A., you
must comply with the applicable Plumbing /Sanitation Code for your area.
Plumbing Hook-Up
1. Remove the shipping cap from the fitting on the rear of the brewer.
2.
STANDARD MODELS:
Securely attach adaptor elbow assembly to the .75-11.5 NH (HOSE THREAD) fit-
ting at the rear of the brewer.
TWIN MODELS:
Securely attach the tube assembly (supplied in parts box) to water supply line. Securely
attach the elbow assemblie to the .75-11.5 NH (HOSE THREAD) fittings at the rear of the brewer. Connect the
tube assembly to the elbows.
3. Flush the water line and Securely attach it to the adaptor elbow.
4. Turn on the water supply.
55502