Bunn DUAL SH DBC Instructions Download Page 1

BUNN-O-MATIC CORPORATION

POST OFFICE BOX 3227

SPRINGFIELD, ILLINOIS 62708-3227

PHONE: (217) 529-6601    FAX: (217) 529-6644

43148.0000A   05/10   ©2010  Bunn-O-Matic Corporation

DUAL SH DBC

FRESHNESS AUDIBLE 

ALERT KIT INSTRUCTIONS

INSTRUCTIONS

WARNING: Disconnect the brewer from the power source before the removal of any panel or replacement of 

any component.

1.  Remove the Top Cover, Front Access Panel and the Server Platform 

Cover from the Brewer.

2.  Remove the Keps Nut securing the Transformer Holddown Strap, Fig 1.

3.  From the Kit, position Relay/Mounting Bracket Assembly over stud and 

secure with the Keps Nut.

4.  Disconnect the white wire of the Main Harness, from the Refill Valve.

5.  Connect the piggy back terminal on the short white wire of the Relay/

Bracket Assembly to the Refill Valve and the white wire of the Main 

FIG 1

GENERAL 

The purpose of these instructions is to serve as a guide when installing one of the following kits and to pro-

vide a list of service replacement parts.

43147.0000  AUDIBLE ALERT KIT:

02618.0000  Relay, 120V SPDT

07441.0000  Bracket, Solenoid/Relay Mounting

02328.0000  Screw, Pan Head #6-32 X .375”

01510.0000  Lockwasher, Ext. Tooth #6

43142.0000  Wiring Harness

43147.0001  AUDIBLE ALERT KIT:

02618.0000  Relay, 120V SPDT

07441.0000  Bracket, Solenoid/Relay Mounting

02328.0000  Screw, Pan Head #6-32 X .375”

01510.0000  Lockwasher, Ext. Tooth #6

43142.0000  Wiring Harness

29969.1040  Circuit Board Assy, Dual SH DBC

(continued)