BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
43148.0000A 05/10 ©2010 Bunn-O-Matic Corporation
DUAL SH DBC
FRESHNESS AUDIBLE
ALERT KIT INSTRUCTIONS
INSTRUCTIONS
WARNING: Disconnect the brewer from the power source before the removal of any panel or replacement of
any component.
1. Remove the Top Cover, Front Access Panel and the Server Platform
Cover from the Brewer.
2. Remove the Keps Nut securing the Transformer Holddown Strap, Fig 1.
3. From the Kit, position Relay/Mounting Bracket Assembly over stud and
secure with the Keps Nut.
4. Disconnect the white wire of the Main Harness, from the Refill Valve.
5. Connect the piggy back terminal on the short white wire of the Relay/
Bracket Assembly to the Refill Valve and the white wire of the Main
FIG 1
GENERAL
The purpose of these instructions is to serve as a guide when installing one of the following kits and to pro-
vide a list of service replacement parts.
43147.0000 AUDIBLE ALERT KIT:
02618.0000 Relay, 120V SPDT
07441.0000 Bracket, Solenoid/Relay Mounting
02328.0000 Screw, Pan Head #6-32 X .375”
01510.0000 Lockwasher, Ext. Tooth #6
43142.0000 Wiring Harness
43147.0001 AUDIBLE ALERT KIT:
02618.0000 Relay, 120V SPDT
07441.0000 Bracket, Solenoid/Relay Mounting
02328.0000 Screw, Pan Head #6-32 X .375”
01510.0000 Lockwasher, Ext. Tooth #6
43142.0000 Wiring Harness
29969.1040 Circuit Board Assy, Dual SH DBC
(continued)