Bunn AXIOM 35-3 Installation & Operating Manual Download Page 1

INSTALLATION & OPERATING GUIDE

BUNN-O-MATIC CORPORATION

POST OFFICE BOX 3227

SPRINGFIELD, ILLINOIS 62708-3227

PHONE: (217) 529-6601    FAX: (217) 529-6644

To ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts 

Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at    

www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog and 
manual updates. For Technical Service, contact Bunn-O-Matic Corporation at 1-800-286-6070.

39130.0000G   12/09  ©2008 Bunn-O-Matic Corporation

Summary of Contents for AXIOM 35-3

Page 1: ...ision of the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quicke...

Page 2: ...e warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive option while the equipment is under warra...

Page 3: ...2440 3230 W 1PH 3 Wire GND 60HZ Optional Field Wiring 120 208 240 V 15 6 17 5 A 2980 3850 W 1PH 3 Wire GND 60HZ 29710 0004 29710 0007 37881 0002 INTRODUCTION This equipment will brew a 1 2 gallon bat...

Page 4: ...10 Set voltage switch to the appropriate position and replace the access panel DV Models Only 11 If plumbing is to be hooked up later be sure the brewer is disconnected from the power source If plumb...

Page 5: ...Suitable For At Least 90 C 194 F FOR USE ONLY ON AN INDIVIDUAL BRANCH CIRCUIT RATED 20 AMPS Dual Voltage Switch in 120V position Dual Voltage Switch in 120 208 240V position 120 208 120 240V AC Singl...

Page 6: ...e counter top Bunn O Matic does not recommend the use of a saddle valve to install the brewer The size and shape of the hole made in the supply line by this type of device may restrict water flow 3913...

Page 7: ...ve no warmers D MAIN ON OFF SWITCH This switch located on the left side of the brewer turns power on and off to all components in the brewer P3633 39130 020608 COFFEE BREWING 1 Begin each brew cycle w...

Page 8: ...g problems in the brewer and takes less than a minute NOTE In the event that the Brew Logic circuit activates compensating for high lime build up it will temporarily disable the Recovery Booster and P...

Page 9: ...r can customize the brewing process to their specifications PROGRAMMING SWITCHES 1 FUNCTION SCREEN This is the display which shows the various functions 2 Right of the display This is used to access t...

Page 10: ...ADY 195 DONE SET TEMP 200 DONE ENTER PASSWORD 0 0 0 EXITING BrewWIZARD BREW LOCKOUT NO DONE YES PROGRAMMING FUNCTIONS FLOW CHART CONT BrewWIZARD ENTER SERVICE NO YES UNITS METRIC DONE ENG SET LANGUAGE...

Page 11: ...ABL WARMER OFF NO DONE YES EnableFreshTimer NO DONE YES ENABLE CLEAN NO DONE YES SET PULSE BREW NO YES ADJUSTMENTS OPTIONAL SETTINGS CONT LEVEL 2 CONT AXIOM VERSION xx xx Return To Main Screen Display...