1
9
English
1.3.3 Connection to an external combustion air supply
The Bullerjan stoves
B
4
have a connecting nozzle for the
supply of combustion air from outside of the installation room.
It’s use can be mandatory in climate controlled buildings with
a controlled loading and venting system.
Stoves that have to be operated by using external air supply
only must undergo a special test in accordance with the re-
quirements of the German Institute for Building Technology
(DIBT). Bullerjan stoves that exhibit this feature are shipped
with a corresponding certificate and are marked at the back
with the "Ü"-sign (tested for EAS/RLU – External Air Supply).
1.4 Assembly of the stove
The special ceramic cover of the Bullerjan
B
4
Keramik
and has to be assembled after delivery.
You will
get a corresponding instruction with the stove. Furthermore
you can find the instruction on: www.bullerjan.com.
The Bullerjan
B
4
in the basic version with steel convection
panels is shipped to you fully assembled.
If you have opted for a version with ceramics, the covering
has to be attached on site. The relevant installation
instructions are included in the packaging of the ceramics.
You can also download these instructions from
www.bullerjan.com.
Important:
I
n order to prevent soiling of the materials, you
should always wear gloves when installing the ceramic
cladding.
When you have positioned your stove at the desired place,
after installing the covers of ceramcis, only a few more
steps have to be taken:
– Use the integrated height adjusters in the pedestals in order
to ensure that the stove is leveled.
– Ensure that the connecting material is professionally installed,
so that the exhaust gases are fully discharged into the chimney.
– The combustion chamber of your stove is equipped with high-
quality vermiculite plates. Please make sure that these plates
have not shifted during transport and are flush on all sides.
2 Firing-/instruction manual
2.1 Initial commissioning
Please ensure that you followed the instructions as
described in section 1.4.
Burning-in:
The Bullerjan stoves are coated with high-quality,
heat-resistant paint, which only reaches its
completely solid
formation and odour nuisance during the first time the stove is
heating up. Please provide for adequate ventilation during this
process, by opening doors and windows. This process should be
completed after a maximum of five hours of a fully burning fire.
Caution hot:
During operation, the surfaces of the wood stove
are very hot! No contact must be made with the stove except at
the handle and the air-supply controller.
Although the door handle of the stoves is insulated, the heat
ing of the door handle can only be delayed and not prevented.
Please use the provided glove to touch the handle of the stove,
when operational.
Important:
The combustion chamber door must be kept
closed for safety reasons; exceptions are during ignition,
during refueling and in the cold state for ash removal.
2.1.
1
Firewood loading and permitted fuels
Below please find an overview of the permitted fuels and
fuel quantities:
Buller
j
an B
4
Nominal heat
output
6,0
kW
8,0
kW 1
0,0
kW
Fuel
quantity
kg /h
1,5
1,8
2,3
Fuel
Type -
recommended
Burning time
Position
throttle valve
Position
air slider
Dry hard-
wood logs
beech
3 logs 3 logs 3 logs
15 cm 15 cm 15 cm
45 Min. 45 Min.
45 Min.
10°
open
10°
45°
open open
1 mark 2 mark
visible
visible
completely
open
Sketches to show the position of the throttle valve:
90° /
completely open
(Ignition phase)
10° /
open
(Operation with 6 and 8 kW)
45° /
open
(Operation with 10 kW)
0° /
closed
(Stove gets out of operation)